Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

被引:44
|
作者
Ding, Xiaorong [1 ]
Zhang, Yuanting [1 ]
Tsang, Hon Ki [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
heart disease; calibration interval; pulse transit time; blood pressure; estimation accuracy; FINGER PHOTOPLETHYSMOGRAM; ARRIVAL-TIME; VALIDATION; HYPERTENSION; DEVICES;
D O I
10.1088/0967-3334/37/2/227
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [21] Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
    Gholamhosseini, Hamid
    Baig, Mirza
    Rastegar, Solmaz
    Linden, Maria
    PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON WEARABLE MICRO AND NANO TECHNOLOGIES FOR PERSONALIZED HEALTH (PHEALTH 2018), 2018, 249 : 77 - 83
  • [22] A Chair for Cuffless Real-time Estimation of Systolic Blood Pressure Based on Pulse Transit Time
    Tang, Zunyi
    Sekine, Masaki
    Tamura, Toshiyo
    Yoshida, Masaki
    Chen, Wenxi
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5118 - 5121
  • [23] Regression-forests-based Estimation of Blood Pressure using the Pulse Transit Time Obtained by Facial Photoplethysmogram
    Yoshioka, Mototaka
    Bounyong, Souksakhone
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 3248 - 3253
  • [24] Pulse Transit Time and Blood Pressure During Cardiopulmonary Exercise Tests
    Wibmer, T.
    Doering, K.
    Kropf-Sanchen, C.
    Ruediger, S.
    Blanta, I.
    Stoiber, K. M.
    Rottbauer, W.
    Schumann, C.
    PHYSIOLOGICAL RESEARCH, 2014, 63 (03) : 287 - 296
  • [25] Effects of Pulse Transit Time and Physiological Differences on Wearable Device based Blood Pressure Estimation
    Hsiao, Chun-Chieh
    Kuo, Hui-Chia
    Lee, Ren-Guey
    Lin, Robert
    2016 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2016, : 242 - 246
  • [26] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [27] An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms
    McCarthy, B. M.
    Vaughan, C. J.
    O'Flynn, B.
    Mathewson, A.
    Mathuna, C. O.
    JOURNAL OF HUMAN HYPERTENSION, 2013, 27 (12) : 744 - 750
  • [28] An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms
    B M McCarthy
    C J Vaughan
    B O'Flynn
    A Mathewson
    C Ó Mathúna
    Journal of Human Hypertension, 2013, 27 : 744 - 750
  • [29] Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration
    Cattivelli, Federico S.
    Garudadri, Harinath
    SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, : 114 - +
  • [30] Continuous and Noninvasive Blood Pressure Estimation by Two-Sensor Measurement of Pulse Transit Time
    Rasool, Anam
    Rafiq, Muqudas
    Nasir, Aisha
    Kashif, Faisal M.
    2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,