Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

被引:44
|
作者
Ding, Xiaorong [1 ]
Zhang, Yuanting [1 ]
Tsang, Hon Ki [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
heart disease; calibration interval; pulse transit time; blood pressure; estimation accuracy; FINGER PHOTOPLETHYSMOGRAM; ARRIVAL-TIME; VALIDATION; HYPERTENSION; DEVICES;
D O I
10.1088/0967-3334/37/2/227
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [1] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Lee, Joonnyong
    Sohn, JangJay
    Park, Jonghyun
    Yang, SeungMan
    Lee, Saram
    Kim, Hee Chan
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [2] Evaluation of transit time-based models in wearable central aortic blood pressure estimation
    Fierro, German
    Armentano, Ricardo
    Silveira, Fernando
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (03)
  • [3] Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models
    Barvik, Daniel
    Cerny, Martin
    Penhaker, Marek
    Noury, Norbert
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2022, 15 : 138 - 151
  • [4] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Joonnyong Lee
    JangJay Sohn
    Jonghyun Park
    SeungMan Yang
    Saram Lee
    Hee Chan Kim
    BioMedical Engineering OnLine, 17
  • [5] Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates
    Feng, Jingjie
    Huang, Zhongyi
    Zhou, Congcong
    Ye, Xuesong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 403 - 413
  • [6] A Compensation Method for Blood Pressure Estimation by Pulse Transit Time
    Liu, Songsong
    Ma, Heather T.
    Chen, Long
    Wang, Xiaopeng
    Yuan, Dezhang
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [7] Enabling Wearable Pulse Transit Time-Based Blood Pressure Estimation for Medically Underserved Areas and Health Equity: Comprehensive Evaluation Study
    Ganti, Venu
    Carek, Andrew M.
    Jung, Hewon
    Srivatsa, Adith, V
    Cherry, Deborah
    Johnson, Levather Neicey
    Inan, Omer T.
    JMIR MHEALTH AND UHEALTH, 2021, 9 (08):
  • [8] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [9] Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates
    Jingjie Feng
    Zhongyi Huang
    Congcong Zhou
    Xuesong Ye
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 403 - 413
  • [10] Pulse waveform as an indicator of baseline offset in pulse transit time based blood pressure estimation
    Lin, Chen
    Zhou, Yuan
    Wang, Hu
    Wang, Yao
    2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 26 - 31