Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

被引:44
作者
Ding, Xiaorong [1 ]
Zhang, Yuanting [1 ]
Tsang, Hon Ki [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
heart disease; calibration interval; pulse transit time; blood pressure; estimation accuracy; FINGER PHOTOPLETHYSMOGRAM; ARRIVAL-TIME; VALIDATION; HYPERTENSION; DEVICES;
D O I
10.1088/0967-3334/37/2/227
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 37 条
[1]   Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors [J].
Baek, Hyun Jae ;
Kim, Ko Keun ;
Kim, Jung Soo ;
Lee, Boreom ;
Park, Kwang Suk .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (02) :145-157
[2]   Validation of continuous blood pressure measurements by pulse transit time: a comparison with invasive measurements in a cardiac intensive care unit [J].
Bartsch, S. ;
Ostojic, D. ;
Schmalgemeier, H. ;
Bitter, T. ;
Westerheide, N. ;
Eckert, S. ;
Horstkotte, D. ;
Oldenburg, O. .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2010, 135 (48) :2406-2412
[3]   ABC of hypertension - Blood pressure measurement Part II - Conventional sphygmomanometry: technique of auscultatory blood pressure measurement [J].
Beevers, G ;
Lip, GYH ;
O'Brien, E .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7293) :1043-1047
[4]   Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010 [J].
Bilo, Grzegorz ;
Zorzi, Cristina ;
Munera, Juan E. Ochoa ;
Torlasco, Camilla ;
Giuli, Valentina ;
Parati, Gianfranco .
BLOOD PRESSURE MONITORING, 2015, 20 (05) :291-294
[5]  
Cattivelli FS, 2009, SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P114, DOI [10.1109/BSN.2009.35, 10.1109/P3644.34]
[6]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[7]   Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform [J].
Choi, Younhee ;
Zhang, Qiao ;
Ko, Seokbum .
COMPUTERS & ELECTRICAL ENGINEERING, 2013, 39 (01) :103-111
[8]   Prevalence, Awareness, Treatment, and Control of Hypertension in Rural and Urban Communities in High-, Middle-, and Low-Income Countries [J].
Chow, Clara K. ;
Teo, Koon K. ;
Rangarajan, Sumathy ;
Islam, Shofiqul ;
Gupta, Rajeev ;
Avezum, Alvaro ;
Bahonar, Ahmad ;
Chifamba, Jephat ;
Dagenais, Gilles ;
Diaz, Rafael ;
Kazmi, Khawar ;
Lanas, Fernando ;
Wei, Li ;
Lopez-Jaramillo, Patricio ;
Lu Fanghong ;
Ismail, Noor Hassim ;
Puoane, Thandi ;
Rosengren, Annika ;
Szuba, Andrzej ;
Temizhan, Ahmet ;
Wielgosz, Andy ;
Yusuf, Rita ;
Yusufali, Afzalhussein ;
Mckee, Martin ;
Liu, Lisheng ;
Mony, Prem ;
Yusuf, Salim .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (09) :959-968
[9]   Influence of arrhythmias on accuracy of non-invasive blood pressure monitors [J].
Cleland, MJ ;
Miller, DR .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (07) :699-705
[10]   LONG-TERM CONTROL OF ARTERIAL BLOOD-PRESSURE [J].
COWLEY, AW .
PHYSIOLOGICAL REVIEWS, 1992, 72 (01) :231-300