Optimal operation of heat exchanger networks with stream split: Only temperature measurements are required

被引:27
|
作者
Jaschke, Johannes [1 ]
Skogestad, Sigurd [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Chem Engn, N-7491 Trondheim, Norway
关键词
Heat exchanger networks; Parallel systems; Self-optimizing control; Optimal operation; OPTIMAL MEASUREMENT COMBINATIONS; RESILIENT PROCESSING PLANTS; SELF-OPTIMIZING CONTROL; CONTROLLED VARIABLES; DESIGN; OPTIMIZATION;
D O I
10.1016/j.compchemeng.2014.03.020
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
For heat exchanger networks with stream splits, we present a simple way of controlling the split ratio. We introduce the "Jaschke Temperature", which for a branch with one exchanger is defined as T-J= (T - T-0)(2)/(T-h - T-0), where To and T are the inlet and outlet temperatures of the split stream (usually cold), and Th is the inlet temperature of the other stream (usually hot). Assuming the heat transfer driving force is given by the arithmetic mean temperature difference, the Jaschke Temperatures of all branches must be equal to achieve maximum heat transfer. The optimal controlled variable is the difference between the Jaschke Temperatures of each branch, which should be controlled to zero. Heat capacity or heat transfer parameters are not needed, and no optimization is required to find the optimal setpoints for the controlled variables. Most importantly, our approach gives near-optimal operation for systems with logarithmic mean temperature difference as driving force. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:35 / 49
页数:15
相关论文
共 50 条
  • [41] Analysis and revamping of heat exchanger networks for crude oil refineries using temperature driving force graphical technique
    Kamel, Dina A.
    Gadalla, Mamdouh A.
    Ashour, Fatma H.
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2018, 20 (02) : 243 - 258
  • [42] Integrating compressors into heat exchanger networks above ambient temperature
    Fu, Chao
    Gundersen, Truls
    AICHE JOURNAL, 2015, 61 (11) : 3770 - 3785
  • [43] Matrix Non-Structural Model and Its Application in Heat Exchanger Network without Stream Split
    Li, Dinghao
    Wang, Jingde
    Sun, Wei
    Zhang, Nan
    PROCESSES, 2023, 11 (06)
  • [44] Integrating expanders into heat exchanger networks above ambient temperature
    Fu, Chao
    Gundersen, Truls
    AICHE JOURNAL, 2015, 61 (10) : 3404 - 3422
  • [45] Optimal energy and cleaning management in heat exchanger networks under fouling
    Georgiadis, MC
    Papageorgiou, LG
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A2) : 168 - 179
  • [46] Dynamic controllability of temperature difference control for the operation of double liquid-only side-stream distillation
    Feng, Zemin
    Wang, Wenhe
    Xu, Di
    Rangaiah, Gade Pandu
    Dong, Lichun
    COMPUTERS & CHEMICAL ENGINEERING, 2022, 164
  • [47] An Environmental and Economic Assessment for Selecting the Optimal Ground Heat Exchanger by Considering the Entering Water Temperature
    Kim, Jimin
    Hong, Taehoon
    Chae, Myeongsoo
    Koo, Choongwan
    Jeong, Jaemin
    ENERGIES, 2015, 8 (08) : 7752 - 7776
  • [48] Simultaneous synthesis of structural-constrained heat exchanger networks with and without stream splits
    Huo Zhaoyi
    Zhao Liang
    Yin Hongchao
    Ye Jianxiong
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 91 (05) : 830 - 842
  • [49] Optimal Operation of an Energy Integrated Batch Reactor - Feed Effluent Heat Exchanger System
    Jogwar, Sujit S.
    Daoutidis, Prodromos
    IFAC PAPERSONLINE, 2015, 48 (08): : 1192 - 1197
  • [50] Simultaneous Synthesis of Heat Exchanger Networks with Pressure Recovery: Optimal Integration between Heat and Work
    Onishi, Viviani C.
    Ravagnani, Mauro A. S. S.
    Caballero, Jose A.
    AICHE JOURNAL, 2014, 60 (03) : 893 - 908