Development of a lumbosacral intervertebral cage prototype for dogs

被引:0
作者
Dias, Raira C. [1 ]
Tsatsakis, Ana Carolina [2 ]
Arias, Monica V. Bahr [1 ]
机构
[1] Univ Estadual Londrina UEL, Dept Clin Vet, Rodovia Celso Garcia Cid PR 445 Km 380, BR-86051990 Londrina, Parana, Brazil
[2] Univ Fed Uberlandia UFU, Curso Design, Ave Joao Naves de Avila 2121, BR-38408100 Uberlandia, MG, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2020年 / 40卷 / 07期
关键词
Lumbosacral; intervertebral cage; prototype; degenerative diseases; surgery; dogs; POLYETHERETHERKETONE CAGES; DISK DEGENERATION; INTERBODY FUSION; TITANIUM CAGE; LUMBAR SPINE; DEVICE; STENOSIS; SPACER; SCREW;
D O I
10.1590/1678-5150-PVB-6505
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Several surgical procedures aim to decompress and/or stabilize the lumbosacral (LS) joint of dogs; however, the lumbar interbody fusion technique, by using a cage combined with a bone graft, is the most indicated and used in human medicine. No specific implant is available for application to the canine lumbosacral joint. Thus, this study measured lumbosacral discs in large dogs, determined whether a human cage model could fit the dogs' L7-S1 intervertebral space, and developed a LS cage prototype for dogs. Ten cadaveric lumbosacral spines from adult dog weighing 20-35kg were used. The dogs had died for reasons unrelated to this study. The vertebral body dimensions and the L7-S1 intervertebral space occupied by the intervertebral disc were measured by lateral and ventrodorsal radiographs and by computed tomography in the dorsal, sagittal, and transverse views. Measurements were also taken of the anatomical specimens in the sagittal and transverse planes. After measuring the intervertebral discs, the following mean measures were obtained for L7-S1 discs: height 12.23mm, dorsal thickness 3.3mm, central thickness 4mm, ventral thickness 5.5mm, and width 24.74mm. The human lumbar cage models from brands LDR, Baumer Orthopedics, Stryker, Synthes, and Vertebral Technologies, Inc. and cervical stabilization cages from the brands B-Braun and Stryker were evaluated and were found to be unsuitable for large dogs. Cervical human cages had measurements similar to those found in this study; however, due to their quadrangular shape, the possibility of being introduced surgically through the surgical accesses available for the articulation between L7-S1 in dogs without injuring the cauda equina or the L7 root is small. A cage model was then developed using 3D modelling software. It was designed for insertion via dorsal laminectomy in the lateral portions of the intervertebral space. To avoid cauda equina lesion, the implant model was developed to be placed laterally to the midline. The cage surface is serrated to prevent using the locking screw to fix it, thus avoiding further injury to nerve structures. The serrated surfaces are also designed to avoid cage migration and promote stability. The prototype allows graft placement in the surrounding intervertebral space, which is fundamental for fusion through integration between the cage and the endplates as well as for bone growth between and around the cage. It was also considered studies on humans showing that the lateral regions of the endplates support a more considerable load. Biomechanical and in vivo studies on the developed model are necessary to evaluate the actual degree of distraction, mobility and the long-term rate of fusion between L7 and S1 and its possible impact on the adjacent motor units, combined or not with dorsal fixation techniques.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 27 条
[1]   The influence of cage positioning and cage type on cage migration and fusion rates in patients with monosegmental posterior lumbar interbody fusion and posterior fixation [J].
Abbushi, Alexander ;
Cabraja, Mario ;
Thomale, Ulrich-Wilhelm ;
Woiciechowsky, Christian ;
Kroppenstedt, Stefan Nikolaus .
EUROPEAN SPINE JOURNAL, 2009, 18 (11) :1621-1628
[2]   Computed tomography of the normal lumbosacral intervertebral disc in 22 dogs [J].
Axlund, TW ;
Hudson, JA .
VETERINARY RADIOLOGY & ULTRASOUND, 2003, 44 (06) :630-634
[3]  
Bebchuck T, 2017, CURRENT TECHNIQUES C, P223
[4]   Comparison of cage designs for transforaminal lumbar interbody fusion: A biomechanical study [J].
Cho, Woojin ;
Wu, Chunhui ;
Mehbod, Amir A. ;
Transfeldt, Ensor E. .
CLINICAL BIOMECHANICS, 2008, 23 (08) :979-985
[5]   Comparison of polyetheretherketone cages with femoral cortical bone allograft as a single-piece interbody spacer in transforaminal lumbar interbody fusion [J].
Cutler, Aaron R. ;
Siddiqui, Saquib ;
Mohan, Avinash L. ;
Hillard, Virany H. ;
Cerabona, Franco ;
Das, Kaushik .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (06) :534-539
[6]  
Farrell M, 2015, ADVANCES IN INTERVERTEBRAL DISC DISEASE IN DOGS AND CATS, P237
[7]  
Fitzpatrick N, 2017, WORLD SMALL AN VET A, P1
[8]   Long-term outcome following lateral foraminotomy as treatment for canine degenerative lumbosacral stenosis [J].
Gomes, Sergio Andrade ;
Lowrie, Mark ;
Targett, Mike .
VETERINARY RECORD, 2018, 183 (11) :352-+
[9]   Mapping the structural properties of the lumbosacral vertebral endplates [J].
Grant, JP ;
Oxland, TR ;
Dvorak, MF .
SPINE, 2001, 26 (08) :889-896
[10]   INVITED REVIEW-APPLICATIONS FOR 3D PRINTERS IN VETERINARY MEDICINE [J].
Hespel, Adrien-Maxence ;
Wilhite, Ray ;
Hudson, Judith .
VETERINARY RADIOLOGY & ULTRASOUND, 2014, 55 (04) :347-358