X-Ray Cargo Inspection: Status and Trends

被引:0
作者
Chen, Gongyin [1 ]
Bjorkholm, Paul [1 ]
Fox, Timothy R. [1 ]
Wilson, Zane [1 ]
Bonsergent, Xavier [1 ]
机构
[1] Varian Med Syst Secur & Inspect Prod, Las Vegas, NV 89119 USA
来源
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY | 2009年 / 1099卷
关键词
X-ray; imaging; cargo;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Over the past several years, x-ray cargo inspection has experienced tremendous growth. There are several hundred systems in use world wide and a few new units are installed every week. Fielded systems are mostly located in north and West Africa, Middle East, Europe (especially Russia), East Asia, and South America. The majority of systems are powered by Varian M3, M6 or M9 Linac x-ray sources. The spatial resolution of these systems is typically 3-5mm, penetration ranges from around 200mm to 450mm of steel and contrast sensitivity is typically 1-4%. Inspection throughput ranges from about 20 trucks per hour to 200 trucks per hour. Currently the systems are primarily used to fight import tax evasion and smuggling of controlled substances. There are a few clear trends: Imaging performance has been steadily improving; a variety of systems have been developed to fit different needs; also, there is a strong effort in material discrimination, or even identification and automatic detection. The last, but not least trend is a shift to security applications. The US government has launched major efforts such as CAARS and JINII to fight nuclear threat and systems that can automatically detect a small amount of high atomic number materials are being developed. This paper only covers RF linear accelerator based X-ray sources, which prevail in the industry. Induction accelerators (Betatrons) have some limited use in low-end imaging systems and high duty factors sources have recently been proposed for study.
引用
收藏
页码:570 / 573
页数:4
相关论文
共 50 条
[41]   The study of using X-ray laminography on printed-circuit board inspection [J].
Chen, H. C. ;
Lin, S. C. .
PROCEEDINGS OF THE 35TH INTERNATIONAL MATADOR CONFERENCE: FORMERLY THE INTERNATIONAL MACHINE TOOL DESIGN AND RESEARCH CONFERENCE, 2007, :221-+
[42]   Current status of X-ray spectrometer development in the SELENE project [J].
Yamamoto, Y. ;
Okada, T. ;
Shiraishi, H. ;
Shirai, K. ;
Arai, T. ;
Ogawa, K. ;
Hosono, K. ;
Arakawa, M. ;
Kato, M. .
ADVANCES IN SPACE RESEARCH, 2008, 42 (02) :305-309
[43]   The characterization of x-ray polycapillary optics with a high-resolution x-ray optical bench [J].
Jach, T ;
Steel, E ;
ChenMayer, H ;
Ullrich, J ;
Downing, RG ;
Thurgate, S .
MULTILAYER AND GRAZING INCIDENCE X-RAY/EUV OPTICS III, 1996, 2805 :192-201
[44]   Dedicated detector for verification of X-ray energy in the linear accelerators for cargo screening and industrial radiography [J].
Kaminski, Przemyslaw ;
Wronka, Slawomir .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2011, 17 (03) :121-128
[45]   Development of Polycapillary X-ray Optics for X-Ray Spectroscopy [J].
Adams, Bernhard W. ;
Attenkofer, Klaus ;
Bond, Justin L. ;
Craven, Christopher A. ;
Cremer, Till ;
O'Mahony, Aileen ;
Minot, Michael J. ;
Popecki, Mark A. .
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
[46]   Soft X-ray calibration for the NeXT X-ray telescope [J].
Maeda, Yoshitonto ;
Hayashi, Takayuki ;
Mori, Hideyuki ;
Nakamura, Ryoko ;
Satoh, Takuro ;
Sekiguchi, Akiko ;
Someya, Kentaro ;
Tamura, Kensuke ;
Ishida, Manabu ;
Osawa, Takeyuki ;
Shirata, Takayuki ;
Suzuki, Masaki ;
Ogasaka, Yasushi ;
Furuzawa, Akhiro ;
Haba, Yoshito ;
Miyazawa, Takuya ;
Kunieda, Hideyo ;
Yamashita, Koujun ;
Okajima, Takashi .
SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
[47]   X-ray phase imaging and X-ray phase tomography [J].
Momose A. .
Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2016, 82 (06) :513-517
[48]   Dual View X-ray Inspection System for Foreign Objects Detection in Canned Food [J].
Lu, Zhiwen ;
Peng, Ningsong .
OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VIII, 2013, 8788
[49]   Digital image analysis of X-ray and neutron radiography for the inspection and the monitoring of nuclear materials [J].
Casalta, S ;
Daquino, GG ;
Metten, L ;
Oudaert, J ;
Van de Sande, A .
NDT & E INTERNATIONAL, 2003, 36 (05) :349-355
[50]   Transformer-based Smart Inspection for Agricultural Products via X-ray Images [J].
Dong, Chaoyu ;
Tan, Alvin Wei Wen ;
Liu, Tong ;
Cheng, Fang ;
Qian, Kemao .
INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONIC ENGINEERING, ICOPEN 2023, 2024, 13069