Technical note: Evaluation of standard ultraviolet absorption ozone monitors in a polluted urban environment

被引:31
作者
Dunlea, E. J.
Herndon, S. C.
Nelson, D. D.
Volkamer, R. M.
Lamb, B. K.
Allwine, E. J.
Grutter, M.
Ramos Villegas, C. R.
Marquez, C.
Blanco, S.
Cardenas, B.
Kolb, C. E.
Molina, L. T.
Molina, M. J.
机构
[1] MIT, Dept Earth Atmospher & Planetary Sci, Cambridge, MA 02139 USA
[2] Aerodyne Res Inc, Billerica, MA 01821 USA
[3] Washington State Univ, Dept Civil & Environm Engn, Lab Atmospher Res, Pullman, WA 99164 USA
[4] Univ Nacl Autonoma Mexico, Ctr Ciencias Atmosfera, Mexico City 04510, DF, Mexico
[5] Gobierno Dist Fed, George Town 11800, Malaysia
[6] Ctr Nacl Invest & Capacitac Ambiental INE, Mexico City 04530, DF, Mexico
关键词
D O I
10.5194/acp-6-3163-2006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of the EPA Federal Equivalent Method (FEM) technique for monitoring ambient concentrations of O-3 via ultraviolet absorption (UV) has been evaluated using data from the Mexico City Metropolitan Area field campaign (MCMA-2003). Comparisons of UV O-3 monitors with open path Differential Optical Absorption Spectroscopy (DOAS) and open path Fourier Transform Infrared (FTIR) spectroscopy instruments in two locations revealed average discrepancies in the measured concentrations between +13% to -18%. Good agreement of two separate open path DOAS measurements at one location indicated that spatial and temporal inhomogeneities were not substantially influencing comparisons of the point sampling and open path instruments. The poor agreement between the UV O-3 monitors and the open path instruments was attributed to incorrect calibration factors for the UV monitors, although interferences could not be completely ruled out. Applying a linear correction to these calibration factors results in excellent agreement of the UV O-3 monitors with the co-located open path measurements; regression slopes of 0.94 to 1.04 and associated R-2 values of >0.89. A third UV O-3 monitor suffered from large spurious interferences, which were attributed to extinction of UV radiation within the monitor by fine particles (<0.2 mu m). The overall performance of this particular monitor was poor owing to a combination of interferences from a contaminated particle filter and/or ozone scrubber. Suggestions for improved operation practices of these UV O-3 monitors and recommendations for future testing are made.
引用
收藏
页码:3163 / 3180
页数:18
相关论文
共 63 条
  • [1] [Anonymous], 2003, ANN BOOK ASTM STAND, V04.05
  • [2] Arshinov M. Yu., 2002, ATMOS OCEAN OPT, V15, P656
  • [3] UV ABSORPTION CROSS-SECTIONS FOR OZONE - THE TEMPERATURE-DEPENDENCE
    BASS, AM
    PAUR, RJ
    [J]. JOURNAL OF PHOTOCHEMISTRY, 1981, 17 (1-2): : 141 - 141
  • [4] EFFECT OF INLET RESIDENCE TIME ON ANALYSIS OF ATMOSPHERIC NITROGEN OXIDES AND OZONE
    BUTCHER, SS
    RUFF, RE
    [J]. ANALYTICAL CHEMISTRY, 1971, 43 (13) : 1890 - &
  • [5] Chase studies of particulate emissions from in-use New York City vehicles
    Canagaratna, MR
    Jayne, JT
    Ghertner, DA
    Herndon, S
    Shi, Q
    Jimenez, JL
    Silva, PJ
    Williams, P
    Lanni, T
    Drewnick, F
    Demerjian, KL
    Kolb, CE
    Worsnop, DR
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 (06) : 555 - 573
  • [6] CAVANAGH RR, 2001, NIST NOAA IND WORKSH
  • [7] Diesel engines: Environmental impact and control - A critical review introduction
    Chow, JC
    Watson, JG
    Berglund, RL
    Biswas, P
    Wu, CY
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (06): : 807 - 808
  • [8] Mexico City basin wind circulation during the MCMA-2003 field campaign
    de Foy, B
    Caetano, E
    Magaña, V
    Zitácuaro, A
    Cárdenas, B
    Retama, A
    Ramos, R
    Molina, LT
    Molina, MJ
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2005, 5 : 2267 - 2288
  • [9] DEFOY B, 2005, ATMOS CHEM PHYS DISC, V5, P2003
  • [10] A review of national monitoring networks in North America
    Demerjian, KL
    [J]. ATMOSPHERIC ENVIRONMENT, 2000, 34 (12-14) : 1861 - 1884