Development of off-line and on-line capillary electrophoresis methods for the screening and characterization of adenosine kinase inhibitors and substrates

被引:34
|
作者
Iqlbal, Jamshed [1 ]
Burbiel, Joachim C. [1 ]
Mueller, Christa E. [1 ]
机构
[1] Inst Pharmazeut, Dept Pharmaceut Chem Poppelsdorf, D-53115 Bonn, Germany
关键词
adenosine derivatives; adenosine kinase assay; capillary electrophoresis; electrophoretically mediated microanalysis; partial-filling technique;
D O I
10.1002/elps.200500944
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast and convenient CE assays were developed for the screening of adenosine kinase (AK) inhibitors and substrates. In the first method, the enzymatic reaction was performed in a test tube and the samples were subsequently injected into the capillary by pressure and detected by their UV absorbance at 260 nm. An MEKC method using borate buffer (pH 9.5) containing 100 mM SDS (method A) was suitable for separating alternative substrates (nucleosides). For the CE determination of AMP formed as a product of the AK reaction, a phosphate buffer (pH 7.5 or 8.5) was used and a constant current (95 mu A) was applied (method 13). The methods employing a fused-silica capillary and normal polarity mode provided good resolution of substrates and products of the enzymatic reaction and a short analysis time of less than 10 min. To further optimize and miniaturize the AK assays, the enzymatic reaction was performed directly in the capillary, prior to separation and quantitation of the product employing electrophoretically mediated microanalysis (EMMA, method C). After hydrodynamic injection of a plug of reaction buffer (20 mM Tris-HCl, 0.2 mM MgCl2, pH 7.4), followed by a plug containing the enzyme, and subsequent injection of a plug of reaction buffer containing 1 mM ATP, 100 mu M adenosine, and 20 mu M UMP as an internal standard (I.S.), as well as various concentrations of an inhibitor, the reaction was initiated by the application of 5 kV separation voltage (negative polarity) for 0.20 min to let the plugs interpenetrate. The voltage was turned off for 5 min (zero-potential amplification) and again turned on at a constant current of -60 mu A to elute the products within 7 min. The method employing a polyacrylamide-coated capillary of 20 cm effective length and reverse polarity mode provided good resolution of substrates and products. Dose-response curves and calculated K-i values for standard antagonists obtained by CE were in excellent agreement with data obtained by the standard radioactive assay.
引用
收藏
页码:2505 / 2517
页数:13
相关论文
共 50 条
  • [1] Determination of creatine kinase activity and phosphocreatine in off-line and on-line modes with capillary electrophoresis
    Fujima, JM
    Danielson, ND
    ANALYTICA CHIMICA ACTA, 1998, 375 (03) : 233 - 241
  • [2] Study of aldehyde oxidase with phthalazine as substrate using both off-line and on-line capillary electrophoresis
    Huang, Shengyun
    Kahsay, Getu
    Adams, Erwin
    Van Schepdael, Ann
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 393 - 398
  • [3] Ionic liquids in enhancing the sensitivity of capillary electrophoresis: Off-line and on-line sample preconcentration techniques
    Abd El-Hady, Deia
    Albishri, Hassan M.
    Waetzig, Hermann
    ELECTROPHORESIS, 2016, 37 (12) : 1609 - 1623
  • [4] Analysis of cephalosporin residues in environmental waters by capillary zone electrophoresis with off-line and on-line preconcentration
    Quesada-Molina, Carolina
    del Olmo-Iruela, Monsalud
    Garcia-Campana, Ana M.
    ANALYTICAL METHODS, 2012, 4 (08) : 2341 - 2347
  • [5] Methods for Off-line/On-line Optimization under Uncertainty
    De Filippo, Allegra
    Lombardi, Michele
    Milano, Michela
    PROCEEDINGS OF THE TWENTY-SEVENTH INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2018, : 1270 - 1276
  • [6] Monitoring adenovirus infections with on-line and off-line methods
    Monica, TJ
    Montgomery, T
    Ayala, JL
    Schoofs, GM
    Whiteley, EM
    Roth, G
    Garbutt, JJ
    Harvey, S
    Castillo, FJ
    BIOTECHNOLOGY PROGRESS, 2000, 16 (05) : 866 - 871
  • [7] On-line preconcentration methods for capillary electrophoresis
    Osbourn, DM
    Weiss, DJ
    Lunte, CE
    ELECTROPHORESIS, 2000, 21 (14) : 2768 - 2779
  • [8] Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration
    Moreno-Gonzalez, David
    Lupion-Enriquez, Isabel
    Garcia-Campana, Ana M.
    ELECTROPHORESIS, 2016, 37 (09) : 1212 - 1219
  • [10] On-line immobilized acetylcholinesterase microreactor for screening of inhibitors from natural extracts by capillary electrophoresis
    Wenao Min
    Weiping Wang
    Jianrong Chen
    Aijun Wang
    Zhide Hu
    Analytical and Bioanalytical Chemistry, 2012, 404 : 2397 - 2405