Optimization model of submerged hollow fiber membrane modules

被引:55
作者
Yoon, SH [1 ]
Kim, HS
Yeom, IT
机构
[1] Nalco Co, Global Res Ctr, Naperville, IL 60563 USA
[2] Sungkyunkwan Univ, Dept Civil Engn, Suwon 440746, South Korea
关键词
modules; economics; water treatment; submerged membrane;
D O I
10.1016/j.memsci.2004.01.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A practical method to obtain optimum design parameters of vertically mounted submerged hollow fiber module was demonstrated to minimize the energy consumption for aeration. Assuming maximum allowable pressure difference in both ends of hollow fiber membrane was 5%, maximum allowable fiber length was calculated for various fluxes and fiber diameters. In case there was no limitation in fiber length, permeate throughput from unit footprint simply increased with fiber diameter. However, if there was a limitation in fiber length/water depth, optimum range of fiber length and lumen diameter existed. For one-side suction, optimum range of outer fiber diameter and fiber length were estimated to be 2.26-3.25 turn and 1.01-1.90 in, respectively, when operating flux was 20-501/m(2) h and a ratio of lumen and outer diameter was 1:2. In the case of two-side suction, fiber length of 1.01-1.90 m and diameter of 1.34-2.05 mm were the optimum range. Finally, optimum design lines, showing the best combinations of lumen diameter and fiber length, were obtained for one-side and two-side suctions. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 14 条
[1]  
[Anonymous], THESIS SEOUL NATL U
[2]   Membrane fouling in membrane bioreactors for wastewater treatment [J].
Chang, IS ;
Le Clech, P ;
Jefferson, B ;
Judd, S .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2002, 128 (11) :1018-1029
[3]   Modeling and optimizing submerged hollow fiber membrane modules [J].
Chang, S ;
Fane, AG ;
Vigneswaran, S .
AICHE JOURNAL, 2002, 48 (10) :2203-2212
[4]   The effect of fibre diameter on filtration and flux distribution - relevance to submerged hollow fibre modules [J].
Chang, S ;
Fane, AG .
JOURNAL OF MEMBRANE SCIENCE, 2001, 184 (02) :221-231
[5]  
CROSSLEY I, 2003, P MEMBR TECHN C AWWA
[6]  
FUJITA K, 1995, J JAPAN WATER WORKS, V64, P12
[7]   Submerged membrane bioreactors: Flat plate or hollow fibre? [J].
Judd, S .
FILTRATION + SEPARATION, 2002, 39 (05) :30-31
[8]  
KANG IJ, 2002, THESIS SEOUL NATL U
[9]  
Kim K.J., 2001, J KOREAN IND ENG CHE, V12, P239
[10]   Comparison of the filtration characteristics between attached and suspended growth microorganisms in submerged membrane bioreactor [J].
Lee, J ;
Ahn, WY ;
Lee, CH .
WATER RESEARCH, 2001, 35 (10) :2435-2445