Dry Eye Exacerbation in Patients Exposed to Desiccating Stress under Controlled Environmental Conditions

被引:86
作者
Lopez-Miguel, Alberto [1 ,2 ]
Teson, Marisa [1 ]
Martin-Montanez, Vicente [1 ,3 ]
Enriquez-de-Salamanca, Amalia [1 ,3 ]
Stern, Michael E. [4 ]
Calonge, Margarita [1 ,3 ]
Gonzalez-Garcia, Maria J. [1 ,3 ]
机构
[1] Univ Valladolid, Inst Univ Oftalmobiol Aplicada IOBA, Valladolid, Spain
[2] Vis I D SL, Valladolid, Spain
[3] Ctr Invest Biomed Red Bioingn Biomat & Nanomed, Valladolid, Spain
[4] Allergan Pharmaceut Inc, Irvine, CA 92715 USA
关键词
TEAR BREAK-UP; OCULAR SURFACE; MATRIX-METALLOPROTEINASE-9; DISEASE; CYTOKINE; RELIABILITY; HUMIDITY; DESIGN;
D O I
10.1016/j.ajo.2014.01.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if controlled environmental conditions can induce acute exacerbations of signs and symptoms in dry eye and asymptomatic subjects. DESIGN: Prospective cross-sectional study. METHODS: Nineteen patients with dry eye and 20 asymptomatic controls were exposed to controlled low humidity (5% relative humidity, desiccating environment) for 2 hours in our Controlled Environmental Research Laboratory at the University of Valladolid. The patients completed the Single-Item Score Dry Eye Questionnaire and the following diagnostic tests were performed before and after exposure: tear osmolarity, phenol red thread test, conjunctival hyperemia, fluorescein tear film break-up time, Schirmer test, and ocular surface vital staining. Sixteen molecules in the tears samples were analyzed by multiplex bead analysis. RESULTS: After exposure, the patients and controls had a significant (P <= .003) increase in corneal staining (from 0.68 +/- 0.15 to 1.16 +/- 0.14 and from 0.50 +/- 0.15 to 1.30 +/- 0.19, respectively), significantly decreased (P <= .01) fluorescein tear film break-up time values (from 2.78 +/- 0.56 seconds to 1.94 +/- 0.24 seconds and from 2.81 +/- 0.24 seconds to 2.13 +/- 0.19 seconds, respectively), and significantly increased (P <= .03) matrix metal-proteinase 9 tear levels (from 10 054.4 +/- 7326.6 pg/mL to 25 744.5 +/- 13 212.4 pg/mL and from 10 620.5 +/- 4494.3 pg/mL to 16 398.7 +/- 5538.3 pg/mL, respectively). In the control group, the epidermal growth factor tear levels decreased significantly (P = .007; from 1872.1 +/- 340.7 pg/mL to 1107.1 +/- 173.6 pg/mL), and interleukin 6 levels increased significantly (P < .001; from 29.6 +/- 5.8 pg/mL to 54.3 +/- 8.3 pg/mL) after exposure. CONCLUSIONS: Adult patients with mild-to-moderate dry eye and asymptomatic subjects of similar ages can experience acute exacerbation in an environmental chamber that resembles the sudden worsening that patients with dry eye experience daily. (C) 2014 by Elsevier Inc. All rights reserved.
引用
收藏
页码:788 / 798
页数:11
相关论文
共 44 条
  • [1] The Effect of Low Humidity on the Human Tear Film
    Abusharha, Ali A.
    Pearce, E. Ian
    [J]. CORNEA, 2013, 32 (04) : 429 - 434
  • [2] MEASUREMENT OF FEELINGS USING VISUAL ANALOGUE SCALES
    AITKEN, RCB
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1969, 62 (10): : 989 - +
  • [3] Factors Predicting the Ocular Surface Response to Desiccating Environmental Stress
    Alex, Anastasia
    Edwards, Austin
    Hays, J. Daniel
    Kerkstra, Michelle
    Shih, Amanda
    de Paiva, Cintia S.
    Pflugfelder, Stephen C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3325 - 3332
  • [4] Dry Eye Disease as an Inflammatory Disorder
    Calonge, Margarita
    Enriquez-de-Salamanca, Amalia
    Diebold, Yolanda
    Gonzalez-Garcia, Maria J.
    Reinoso, Roberto
    Herreras, Jose M.
    Corell, Alfredo
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2010, 18 (04) : 244 - 253
  • [5] RELIABILITY OF THE TEAR BREAK-UP TIME TECHNIQUE OF ASSESSING TEAR STABILITY AND THE LOCATIONS OF THE TEAR BREAK-UP IN HONG-KONG CHINESE
    CHO, P
    BROWN, B
    CHAN, I
    CONWAY, R
    YAP, M
    [J]. OPTOMETRY AND VISION SCIENCE, 1992, 69 (11) : 879 - 885
  • [6] Production and Activity of Matrix Metalloproteinase-9 on the Ocular Surface Increase in Dysfunctional Tear Syndrome
    Chotikavanich, Suksri
    de Paiva, Cintia S.
    Li, De Quan
    Chen, Joseph J.
    Bian, Fang
    Farley, William J.
    Pflugfelder, Stephen C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (07) : 3203 - 3209
  • [7] SCHIRMER TEST - A CLOSER LOOK
    CLINCH, TE
    BENEDETTO, DA
    FELBERG, NT
    LAIBSON, PR
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1983, 101 (09) : 1383 - 1386
  • [8] Ocular Mucin Gene Expression Levels as Biomarkers for the Diagnosis of Dry Eye Syndrome
    Corrales, Rosa M.
    Narayanan, Srihari
    Fernandez, Itziar
    Mayo, Agustin
    Galarreta, David J.
    Fuentes-Paez, Graciana
    Chaves, Felipe J.
    Herreras, Jose M.
    Calonge, Margarita
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 8363 - 8369
  • [9] Correlations Among Symptoms, Signs, and Clinical Tests in Evaporative-Type Dry Eye Disease Caused by Meibomian Gland Dysfunction (MGD)
    Cuevas, Miguel
    Gonzalez-Garcia, Maria J.
    Castellanos, Evangelina
    Quispaya, Rolando
    de la Parra, Paola
    Fernandez, Itziar
    Calonge, Margarita
    [J]. CURRENT EYE RESEARCH, 2012, 37 (10) : 855 - 863
  • [10] Influence of indoor design air parameters on energy consumption of heating and air conditioning
    Ding, Yan
    Fu, Qiang
    Tian, Zhe
    Li, Meixia
    Zhu, Neng
    [J]. ENERGY AND BUILDINGS, 2013, 56 : 78 - 84