Dual energy subtraction digital radiography - Technical considerations, clinical applications, and imaging pitfalls

被引:22
作者
Gilkeson, Robert C. [1 ]
Sachs, Peter B. [1 ]
机构
[1] Univ Hosp Cleveland, Case Med Sch, Dept Radiol, Cleveland, OH 44106 USA
关键词
dual energy; digital radiography; chest disease;
D O I
10.1097/01.rti.0000213646.34417.be
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Emerging applications in digital radiography offer exciting advances in the evaluation of lung disease. Dual energy subtraction techniques have been recognized as a promising technique in the detection and characterization of pulmonary nodules. This essay will demonstrate a significantly expanded diagnostic role in the assessment of cardiothoracie disease with dual energy subtraction and digital radiography.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 22 条
[1]  
AUSTIN JH, 1992, RADIOLOGY, V182, P8
[2]   The solitary pulmonary nodule on chest radiography: Can we really tell if the nodule is calcified! [J].
Berger, WG ;
Erly, WK ;
Krupinski, EA ;
Standen, JR ;
Stern, RG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :201-204
[3]   Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography [J].
Bernhardt, TM ;
Otto, D ;
Reichel, G ;
Ludwig, K ;
Seifert, S ;
Kropf, S ;
Rapp-Bernhardt, U .
RADIOLOGY, 1999, 213 (02) :445-454
[4]  
Detrano R, 1992, Int J Card Imaging, V8, P209, DOI 10.1007/BF01146839
[5]   Digital chest radiography: Effect of temporal subtraction images on detection accuracy [J].
Difazio, MC ;
MacMahon, H ;
Xu, XW ;
Tsai, P ;
Shiraishi, J ;
Armato, SG ;
Doi, K .
RADIOLOGY, 1997, 202 (02) :447-452
[6]   Dual-energy chest radiography with a flat-panel digital detector:: Revealing calcified chest abnormalities [J].
Fischbach, F ;
Freund, T ;
Röttgen, R ;
Engert, U ;
Felix, R ;
Ricke, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (06) :1519-1524
[7]   Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography [J].
Floyd, CE ;
Warp, RJ ;
Dobbins, JT ;
Chotas, HG ;
Baydush, AH ;
Vargas-Voracek, R ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :683-688
[8]   Original report. Digital radiography with dual-energy subtraction: Improved evaluation of cardiac calcification. [J].
Gilkeson, RC ;
Novak, RD ;
Sachs, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1233-1238
[9]   Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331
[10]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105