Modification of the Ti-6Al-4V alloy by ion implantation of calcium and/or phosphorus

被引:17
|
作者
Tsyganov, I [1 ]
Wieser, E [1 ]
Matz, W [1 ]
Reuther, H [1 ]
Richter, E [1 ]
机构
[1] Forschungszentrum Rossendorf EV, Inst Ion Beam Phys & Mat Res, D-01314 Dresden, Germany
来源
关键词
titanium alloys; ion implantation; phase formation;
D O I
10.1016/S0257-8972(02)00190-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Ion implantation of Ca and/or P into Ti or Ti alloys is of interest in order to enhance mechanical properties and biocompatibility for medical applications. In this study, the microstructural changes of the implanted surface layer were studied. Surface near implantation of high doses of calcium results in an oxidation of the modified layer and the formation of CaO. For deeper calcium implantations, precipitation of the metastable hexagonal modification of calcium has been observed instead of the cubic equilibrium phase. Besides these new phases, partial amorphization is observed. High dose implantation of phosphorus leads mainly to amorphization of the implanted layer. This hinders the reaction with oxygen during implantation and room temperature aging. Hi-h dose double implantation with P followed by Ca also leads to partial amorphization. No indication for new phases containing Ca and P is found. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 50 条
  • [1] Surface modification of Ti-6Al-4V alloy by nitrogen ion implantation
    Budzynski, P.
    Youssef, A. A.
    Sielanko, J.
    WEAR, 2006, 261 (11-12) : 1271 - 1276
  • [2] ION-IMPLANTATION OF SURGICAL TI-6AL-4V ALLOY
    WILLIAMS, JM
    BUCHANAN, RA
    MATERIALS SCIENCE AND ENGINEERING, 1985, 69 (01): : 237 - 246
  • [3] WEAR IMPROVEMENT OF SURGICAL TI-6AL-4V ALLOY BY ION-IMPLANTATION
    WILLIAMS, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 10-1 (MAY): : 539 - 544
  • [4] Blistering in alloy Ti-6Al-4V from H+ ion implantation
    B. K. Singh
    V. Singh
    Bulletin of Materials Science, 2010, 33 : 179 - 183
  • [5] FATIGUE LIFE IMPROVEMENT OF TI-6AL-4V ALLOY BY ION-IMPLANTATION
    VARDIMAN, RG
    KANT, RA
    CROOKER, TW
    RATH, BB
    JOURNAL OF METALS, 1979, 31 (12): : 58 - 58
  • [6] Blistering in alloy Ti-6Al-4V from H+ ion implantation
    Singh, B. K.
    Singh, V.
    BULLETIN OF MATERIALS SCIENCE, 2010, 33 (02) : 179 - 183
  • [7] Surface Modification of the EBM Ti-6Al-4V Alloy by Pulsed Ion Beam
    Pushilina, Natalia
    Stepanova, Ekaterina
    Stepanov, Andrey
    Syrtanov, Maxim
    METALS, 2021, 11 (03) : 1 - 13
  • [8] A comparative study of Ti+N and W ion implantation into Ti-6Al-4V alloy
    Tek, Z.
    Oeztarhan, A.
    Selvi, S.
    SURFACE & COATINGS TECHNOLOGY, 2007, 201 (19-20): : 8170 - 8174
  • [9] 9 MeV Au ion implantation into Ti and Ti-6Al-4V
    R. Trejo-Luna
    L. R. De La Vega
    J. Rickards
    C. Falcony
    M. Jergel
    Journal of Materials Science, 2001, 36 : 503 - 510
  • [10] 9 MeV au ion implantation into Ti and Ti-6Al-4V
    Trejo-Luna, R
    De la Vega, LR
    Rickards, J
    Falcony, C
    Jergel, M
    JOURNAL OF MATERIALS SCIENCE, 2001, 36 (02) : 503 - 510