Fabrication of carbon nanotubes/poly(1,2-diaminobenzene) nanoporous composite via multipulse chronoamperometric electropolymerization process and its electrocatalytic property toward oxidation of NADH

被引:48
作者
Zeng, Jinxiang [1 ]
Gao, Xiaohua [1 ]
Wei, Wanzhi [1 ]
Zhai, Xiurong [1 ]
Yin, Jian [1 ]
Wu, Ling [1 ]
Liu, Xiaoyin [1 ]
Liu, Kai [1 ]
Gong, Shuguo [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
multipulse chronoamperometric electropolymeriziation; carbon nanotubes; 1,2-diaminobenzene; nanoporous composite; NADH;
D O I
10.1016/j.snb.2006.03.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method was proposed for fabrication of a carbon nanotubes/poly(1,2-diaminobenzene) nanoporous composite based electrode. The poly(1,2-diaminobenzene) was deposited onto the surface of a glassy carbon electrode (GCE) modified with multi-wall carbon nanotubes (MWNTs) via multipulse chronoamperometric electropolymerization (MCE) process. Compared with the composite prepared by conventional electropolymerization (CE), the electronic and ionic transport capacity of the MCE-based composite were significantly improved due to its unique nanoporous structure. The surface of the composite-modified GCE was characterized with scanning electron microscopy (SEM) and cyclic voltammetry (CV). The nanoporous MCE-based electrode was applied to determination of NADH at a much low potential of 70 mV, and a linear range from 2.0 mu M to 4.0 mM was observed with fast response (within 5 s) and a lower detection limit of 0.5 mu M (based on S/N = 3). In comparison, a narrow linear range from 5.0 mu M to 2.0 mM, slower response (up to 15 s) and a higher detection limit of 3.0 mu M (based on S/N = 3) was obtained with the electrode prepared by CE. The wider linear range, lower detection limit and fast response of the MCE-based electrode implies that the new method proposed can provide more excellent platforms for sensitive electrochemical sensing and biosensing. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:595 / 602
页数:8
相关论文
共 46 条
[21]  
2-B
[22]   FLEXIBLE POLYANILINE [J].
KITANI, A ;
KAYA, M ;
TSUJIOKA, SI ;
SASAKI, K .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1988, 26 (06) :1531-1539
[23]   Single-wall carbon nanotube/conjugated polymer photovoltaic devices [J].
Kymakis, E ;
Amaratunga, GAJ .
APPLIED PHYSICS LETTERS, 2002, 80 (01) :112-114
[24]   STUDIES OF THE FORMATION AND REDOX TRANSFORMATION OF POLY(O-PHENYLENEDIAMINE) FILMS USING A QUARTZ-CRYSTAL MICROBALANCE [J].
MARTINUSZ, K ;
CZIROK, E ;
INZELT, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 379 (1-2) :437-444
[25]   EFFECTS OF ADSORPTION, ELECTRODE MATERIAL, AND OPERATIONAL VARIABLES ON OXIDATION OF DIHYDRONICOTINAMIDE ADENINE-DINUCLEOTIDE AT CARBON ELECTRODES [J].
MOIROUX, J ;
ELVING, PJ .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1056-1062
[26]   Basal plane pyrolytic graphite modified electrodes: Comparison of carbon nanotubes and graphite powder as electrocatalysts [J].
Moore, RR ;
Banks, CE ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (10) :2677-2682
[27]   Properties of regioregular poly(3-octylthiophene)/multi-wall carbon nanotube composites [J].
Musa, I ;
Baxendale, M ;
Amaratunga, GAJ ;
Eccleston, W .
SYNTHETIC METALS, 1999, 102 (1-3) :1250-1250
[28]   Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].
Musameh, M ;
Wang, J ;
Merkoci, A ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) :743-746
[29]   Enhancing the performance of an electrochromic device by template synthesis of the active layers [J].
Neves, S ;
Santos, RF ;
Gazotti, WA ;
Fonseca, CP .
THIN SOLID FILMS, 2004, 460 (1-2) :300-305
[30]   FACTORS AFFECTING THE GROWTH OF THICK POLYANILINE FILMS BY THE CYCLIC VOLTAMMETRY TECHNIQUE [J].
NUNZIANTE, P ;
PISTOIA, G .
ELECTROCHIMICA ACTA, 1989, 34 (02) :223-228