Amperometric biosensor with physically immobilized glucose oxidase on a PVA cryogel membrane

被引:28
|
作者
Doretti, L [1 ]
Ferrara, D [1 ]
Gattolin, P [1 ]
Lora, S [1 ]
机构
[1] CNR,IST FOTOCHIM & RADIAZ ALTA ENERGIA,I-35020 LEGNARO,PADOVA,ITALY
关键词
biosensors glucose oxidase; physical immobilization; PVA cryogels;
D O I
10.1016/S0039-9140(96)02130-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of physically immobilizing a biomolecule of analytical interest in poly(vinyl alcohol) cryogels was developed to obtain suitable biosensors. An amperometric glucose sensor was constructed using glucose oxidase immobilized on membranes obtained by a freezing-thawing cyclic process; No chemical cross-linking agent was used. Sensor behaviour was evaluated electrochemically with a hydrogen peroxide electrode. The glucose content in standard solutions was determined and linear calibration curves in the 5 x 10(-5)-3 x 10(-3) mol l(-1) range were obtained. Temperature and pH effects on the electrochemical response were described and kinetic parameters in the immobilized system were evaluated. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:859 / 866
页数:8
相关论文
共 50 条
  • [21] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14
  • [22] Studies on dynamic behavior of the biosensor based on immobilized glucoamylase glucose oxidase membrane
    Gondo, S
    Kim, C
    Hirata, S
    Morishita, M
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (05): : 395 - 401
  • [23] Amperometric Biosensor Based on Galactose Oxidase Immobilized in Clay Matrix
    Charmantray, Franck
    Touisni, Nadia
    Hecquet, Laurence
    Mousty, Christine
    ELECTROANALYSIS, 2013, 25 (03) : 630 - 635
  • [24] Gold nanoparticles-coated eggshell membrane with immobilized glucose oxidase for fabrication of glucose biosensor
    Zheng, Baozhan
    Xie, Shunping
    Qian, Lei
    Yuan, Hongyan
    Xiao, Dan
    Choi, Martin M. F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (01) : 49 - 55
  • [25] Stability studies on immobilized glucose oxidase using an amperometric biosensor - Effect of protein based stabilizing agents
    Gouda, MD
    Thakur, MS
    Karanth, NG
    ELECTROANALYSIS, 2001, 13 (10) : 849 - 855
  • [26] Genetic modification of glucose oxidase for improving performance of an amperometric glucose biosensor
    Chen, LQ
    Zhang, XE
    Xie, WH
    Zhou, YF
    Zhang, ZP
    Cass, AEG
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (10): : 851 - 857
  • [27] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes
    Kong, Tao
    Chen, Yang
    Ye, Yiping
    Zhang, Kun
    Wang, Zhenxing
    Wang, Xiaoping
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 344 - 350
  • [28] GLUCOSE BIOSENSOR USING GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE
    PARENTE, AH
    MARQUES, ETA
    AZEVEDO, WM
    DINIZ, FB
    MELO, EHM
    FILHO, JLL
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 37 (03) : 267 - 273
  • [29] AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION
    RISHPON, J
    GOTTESFELD, S
    CAMPBELL, C
    DAVEY, J
    ZAWODZINSKI, TA
    ELECTROANALYSIS, 1994, 6 (01) : 17 - 21
  • [30] Amperometric detection of glucose with glucose oxidase immobilized in layered double hydroxides
    Shan, Dan
    Yao, Wenjuan
    Xue, Huaiguo