Dosimetric comparison of six epithermal neutron beams using an ellipsoidal water phantom

被引:0
|
作者
Binns, PJ [1 ]
Riley, KJ [1 ]
Harling, OK [1 ]
机构
[1] MIT, Nucl Reactor Lab, Cambridge, MA 02139 USA
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The physical performance of the epithermal neutron beams used by the principal NCT facilities to accrue clinical results in Western Europe and USA were assessed under equivalent irradiation conditions. Using a common dosimetry method variations in the separate dose components for the different facilities were quantified both in-air and in an ellipsoidal phantom. Figures of merit were generated to assess beam performance under realistic conditions akin to therapy. The overall performance characteristics of the different beams are generally not markedly different except for the available dose rates, which vary by a factor greater than six.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 50 条
  • [31] Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms
    Matsushima, Luciana C.
    Veneziani, Glauco R.
    Sakuraba, Roberto K.
    da Cruz, Jose C.
    Campos, Leticia L.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1363 - 1366
  • [32] Dosimetric Comparison of Patient Specific IMRT QA Using Varian DynaLog Files and TPS Calculations in a Phantom Geometry
    Qiu, Y.
    Kim, S.
    Mavroidis, P.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [33] A phantom experiment for the evaluation of whole body exposure during BNCT using cyclotron-based epithermal neutron source (C-BENS)
    Tsukamoto, T.
    Tanaka, H.
    Yoshinaga, H.
    Mitsumoto, T.
    Maruhashi, A.
    Ono, K.
    Sakurai, Y.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1830 - 1833
  • [34] Boron neutron capture therapy using mixed epithermal and thermal neutron beams in patients with malignant glioma - Correlation between radiation dose and radiation injury and clinical outcome
    Kageji, Teruyoshi
    Nagahiro, Shinji
    Matsuzaki, Kazuhito
    Mizobuchi, Yoshifumi
    Toi, Hiroyuki
    Nakagawa, Yoshinobu
    Kumada, Hiroaki
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05): : 1446 - 1455
  • [35] Inter-comparison among fast neutron dosimetric services using PADC material of different composition
    Fantuzzi, E
    Boschung, M
    Fiechtner, A
    Hoffmann, J
    McKeever, R
    Stokes, R
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 487 - 492
  • [36] MEASUREMENT AND ANALYSIS ON NEUTRON-FLUX DISTRIBUTIONS IN A HEAVY-WATER PHANTOM USING THE KUR NEUTRON GUIDE TUBE FOR BNCT
    KOBAYASHI, T
    ONO, M
    KANDA, K
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 101 - 103
  • [37] Comparison of list mode data acquisition and shift register measurements using the large epithermal neutron multiplicity counter (LEMC)
    McElroy, R. D., Jr.
    Croft, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (03) : 725 - 730
  • [38] Comparison of list mode data acquisition and shift register measurements using the large epithermal neutron multiplicity counter (LEMC)
    R. D. McElroy
    S. Croft
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 725 - 730
  • [39] DOSIMETRIC COMPARISON OF IMRT USING HELICAL PHOTON BEAMS VERSUS RANGE-MODULATED ELECTRON BEAMS IN RADIOTHERAPY OF BREAST AND CHEST WALL CANCER
    Gargioni, E.
    Cremers, F.
    Gauer, T.
    Engel, K.
    Goy, Y.
    Petersen, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S126 - S126
  • [40] Boron neutron capture therapy using reactor epithermal neutron beams could effectively control in-transit and lymph node metastases originating from a cutaneous malignant melanoma
    Omori, Mamiko
    Fujiwara, Susumu
    Shimizu, Hideki
    Ikeda, Tetsuya
    Bito, Toshinori
    Suzuki, Minoru
    Masunaga, Shin-ichiro
    Ono, Koji
    Nishigori, Chikako
    JOURNAL OF DERMATOLOGY, 2018, 45 (04): : E90 - E91