Separation and detection of explosives on a microchip using micellar electrokinetic chromatography and indirect laser-induced fluorescence

被引:127
作者
Wallenborg, SR [1 ]
Bailey, CG [1 ]
机构
[1] Sandia Natl Labs, Livermore, CA 94551 USA
关键词
D O I
10.1021/ac991382y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for sensitive detection on a microfabricated chip is presented. Indirect laser-induced-fluorescence (IDLIF) was used to detect explosive compounds after separation by micellar electrokinetic chromatography (MEKC), The detection setup was used in an epifluorescence configuration with excitation provided by a near-IR diode laser operating at 750 nm, To achieve indirect detection, a low concentration of a dye (5 mu M Cy7) was added to the running buffer as a visualizing agent. Using this methodology, a sample containing 14 explosives (EPA 8330 mixture) was examined. Concentrations of 1 ppm of trinitrobenzene (TNB), trinitrotoluene (TNT), dinitrobenzene (DNB), tetryl, and 2,4-dinitrotoluene (2,4-DNT) could be detected with S/N ratios between 3 and 10, Analyses showing 10 peaks, with plate numbers on the order of 60 000, were completed within 60 s using a 65 mm long separation channel. The three isomers of nitrotoluene (2-, 3-, and 4-nitrotoluene) were not resolved. Additionally, the two nitramines (HMX and RDX) could only be detected at much higher concentrations, likely due to the low fluorescence quenching efficiencies of these compounds. The analysis method was also used to separate and detect nitroaromatic compounds in extracts from spiked soil samples. The presence of 1 ppm (1 mu g of analyte/1 g of soil) of TNB, DNB, TNT, tetryl, 2,4-DNT, 2,6-DNT, 2-NH2-4,6-DNT, and 4-NH2-2,6-DNT could readily be detected. In the interest of increasing the sensitivity of the analysis, various on-chip injection schemes were evaluated. It was found that a 250 mu m double-T injector gave a 35% increase in peak signal compared to a straight-cross injector, which is less than expected based on injected volume.
引用
收藏
页码:1872 / 1878
页数:7
相关论文
共 45 条
[1]   INDIRECT FLUORESCENCE DETECTION IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
AMANKWA, LN ;
KUHR, WG .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1733-1737
[2]   Separation of explosives using capillary electrochromatography [J].
Bailey, CG ;
Yan, C .
ANALYTICAL CHEMISTRY, 1998, 70 (15) :3275-3279
[4]   DETERMINATION OF NITRO AROMATIC, NITRAMINE, AND NITRATE ESTER EXPLOSIVE COMPOUNDS IN EXPLOSIVE MIXTURES AND GUNSHOT RESIDUE BY LIQUID-CHROMATOGRAPHY AND REDUCTIVE ELECTROCHEMICAL DETECTION [J].
BRATIN, K ;
KISSINGER, PT ;
BRINER, RC ;
BRUNTLETT, CS .
ANALYTICA CHIMICA ACTA, 1981, 130 (02) :295-311
[5]  
Desiderio C, 1999, ELECTROPHORESIS, V20, P525
[6]  
*DION CORP, 136 DION CORP
[7]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[8]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[9]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[10]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10