Three-dimensional accuracy assessment of eye surgeons

被引:0
|
作者
Hotraphinyo, LF [1 ]
Riviere, CN [1 ]
机构
[1] Carnegie Mellon Univ, Dept Elect & Comp Engn, Pittsburgh, PA 15213 USA
关键词
microsurgery; accuracy; optical sensing;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Overall manual accuracy in simulated microsurgery has been studied. Three eye surgeons have been tested thus far. Subjects attempted to hold a microsurgical instrument still for 30 s and its 3-D tip position was recorded. RMS error, overall motion range were calculated and spectral analysis was performed for each axis. The RMS error was between 54 mum and 118 mum and the overall range of motion was between 239 mum and 588 mum, depending on the axis. Substantial low frequency motion was present. Between 73.5% and 83.7% of the total power was found to be below 3 Hz, depending on the axis.
引用
收藏
页码:3458 / 3461
页数:4
相关论文
共 50 条
  • [21] Anticipating the three-dimensional consequences of eye movements
    Wexler, M
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (04) : 1246 - 1251
  • [22] A biomorphic simulator of three-dimensional eye movements
    Bang, YB
    Shin, BH
    Paik, JK
    Lee, C
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS 2003, VOL 1-3, 2003, : 714 - 719
  • [23] Accuracy of three-dimensional analysis of regularized singularities
    Benvenuti, Elena
    Ventura, Giulio
    Ponara, Nicola
    Tralli, Antonio
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2015, 101 (01) : 29 - 53
  • [24] CRITERIA OF ACCURACY IN TESTS FOR THREE-DIMENSIONAL VIBRATIONS
    BOZHKO, AE
    SHPACHUK, VP
    MEASUREMENT TECHNIQUES, 1980, 23 (07) : 607 - 611
  • [25] In vitro measurement accuracy of three-dimensional ultrasound
    Zotz, RJ
    Trabold, T
    Bock, A
    Kollmann, C
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (02): : 149 - 156
  • [26] Three-dimensional geopositioning accuracy of Ikonos imagery
    Fraser, CS
    Hanley, HB
    Yamakawa, T
    PHOTOGRAMMETRIC RECORD, 2002, 17 (99): : 465 - 479
  • [27] Three-dimensional imaging improves mammogram accuracy
    Pirisi, Angela
    LANCET ONCOLOGY, 2013, 14 (01): : E9 - E9
  • [28] Geometric accuracy of three-dimensional molecular overlays
    Chen, Qi
    Higgs, Richard E.
    Vieth, Michal
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2006, 46 (05) : 1996 - 2002
  • [29] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [30] An Investigation of Dimensional Accuracy of Parts Produced by Three-Dimensional Printing
    Islam, M. N.
    Boswell, Brian
    Pramanik, A.
    WORLD CONGRESS ON ENGINEERING - WCE 2013, VOL I, 2013, : 522 - 525