Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:14
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY DETECTION OF BRUCH MEMBRANE AND CHORIOCAPILLARIS ABNORMALITIES IN SORSBY MACULAR DYSTROPHY
    Iyer, Prashanth G.
    Zhou, Hao
    Zhang, Qinqin
    Chu, Zhongdi
    Shen, Mengxi
    Shi, Yingying
    Liu, Jeremy
    Trivizki, Omer
    Lam, Byron L.
    Wang, Ruikang K.
    Gregori, Giovanni
    Rosenfeld, Philip J.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (09): : 1645 - 1654
  • [22] En face swept-source optical coherence tomography in neovascular age-related macular degeneration
    Flores-Moreno, Ignacio
    Arias-Barquet, Luis
    Rubio-Caso, Marcos J.
    Ruiz-Moreno, Jose M.
    Duker, Jay S.
    Caminal, Josep M.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (09) : 1260 - 1267
  • [23] Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer
    Lu, Weicong
    Li, Yue
    Savini, Giacomo
    Song, Benhao
    Hu, Qingjie
    Wang, Qinmei
    Bao, Fangjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03) : 298 - 304
  • [24] Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry
    Kunert, Kathleen S.
    Peter, Monika
    Blum, Marcus
    Haigis, Wolfgang
    Sekundo, Walter
    Schuetze, Juliane
    Bueehren, Tobias
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) : 76 - 83
  • [25] Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
    Hanumunthadu, Daren
    Keane, Pearse A.
    Balaskas, Konstantinos
    Dubis, Adam M.
    Kalitzeos, Angelos
    Michaelides, Michel
    Patel, Praveen J.
    OPHTHALMOLOGY AND THERAPY, 2021, 10 (04) : 913 - 922
  • [26] Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
    Sakai, Daiki
    Yokota, Satoshi
    Maeda, Akiko
    Hirami, Yasuhiko
    Nakamura, Makoto
    Kurimoto, Yasuo
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [27] Clinical Observation of Choroidal Osteoma Using Swept-Source Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Xuan, Yi
    Chang, Qing
    Zhang, Yongjin
    Ye, Xiaofeng
    Liu, Wei
    Li, Lei
    Wang, Keyan
    Zhou, Jian
    Wang, Min
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [28] Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Ruiss, Manuel
    Pilwachs, Caroline
    Georgiev, Stefan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10) : 1302 - 1307
  • [29] Characterization of Macular Structural and Microvascular Changes in Thalamic Infarction Patients: A Swept-Source Optical Coherence Tomography-Angiography Study
    Ye, Chen
    Kwapong, William Robert
    Tao, Wendan
    Lu, Kun
    Pan, Ruosu
    Wang, Anmo
    Liu, Junfeng
    Liu, Ming
    Wu, Bo
    BRAIN SCIENCES, 2022, 12 (05)
  • [30] COMPARING FUNDUS FLUORESCEIN ANGIOGRAPHY AND SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN THE EVALUATION OF DIABETIC MACULAR PERFUSION
    La Mantia, Alberto
    Kurt, Rengin A.
    Mejor, Samantha
    Egan, Catherine A.
    Tufail, Franzco Adnan
    Keane, Pearse A.
    Sim, Dawn A.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (05): : 926 - 937