Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:14
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) : 1165 - 1172
  • [2] Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry
    Higashiyama, Tomoaki
    Mori, Hazuki
    Nakajima, Fumi
    Ohji, Masahito
    PLOS ONE, 2018, 13 (04):
  • [3] Macular Choroidal Thickening in Keratoconus Patients: Swept-Source Optical Coherence Tomography Study
    Gutierrez-Bonet, Rosa
    Ruiz-Medrano, Jorge
    Pena-Garcia, Pablo
    Catanese, Muriel
    Sadeghi, Yalda
    Hashemi, Katayoon
    Gabison, Eric
    Ruiz-Moreno, Jose M.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [4] Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients
    Chirapapaisan, Chareenun
    Srivannaboon, Sabong
    Chonpimai, Pratuangsri
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 186 - 191
  • [5] Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    Arriola-Villalobos, P.
    Almendral-Gomez, J.
    Garzon, N.
    Ruiz-Medrano, J.
    Fernandez-Perez, C.
    Martinez-de-la-Casa, J. M.
    Diaz-Valle, D.
    EYE, 2017, 31 (03) : 437 - 442
  • [6] Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Yamamoto, Mana
    Kaga, Tatsushi
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2021, 64 (04) : 595 - 603
  • [7] DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Sano, Masahiko
    Inoue, Makoto
    Itoh, Yuji
    Kita, Yoshiyuki
    Hirota, Kazunari
    Koto, Takashi
    Hirakata, Akito
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (08): : 1483 - 1491
  • [8] Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster
    Huang, Jinhai
    Savini, Giacomo
    Hoffer, Kenneth J.
    Chen, Hao
    Lu, Weicong
    Hu, Qingjie
    Bao, Fangjun
    Wang, Qinmei
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 493 - 498
  • [9] Swept-source Optical Coherence Tomography Angiography Findings in Uveitic Cystoid Macular Edema
    Khochtali, Sana
    Abroug, Nesrine
    Megzari, Kenza
    Gargouri, Mohamed Ali
    Ksiaa, Imen
    Ben Amor, Hager
    Saihi, Emna
    Khairallah, Moncef
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2019, 27 (08) : 1211 - 1223
  • [10] Clinical Evaluation of a New Swept-Source Optical Coherence Biometer That Uses Individual Refractive Indices to Measure Axial Length in Cataract Patients
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Yamamoto, Mana
    Kaga, Tatsushi
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2019, 62 (01) : 11 - 23