MR imaging with metal artifact-reducing sequences and gadolinium contrast agent in a case-control study of periprosthetic abnormalities in patients with metal-on-metal hip prostheses

被引:13
作者
Mueller, Gunilla M. [1 ]
Mansson, Sven [3 ]
Mueller, Markus F. [1 ]
von Schewelov, Thord [2 ]
Nittka, Mathias [5 ]
Ekberg, Olle [1 ]
Lundin, Bjorn [4 ]
机构
[1] Lund Univ, Dept Radiol, Skane Univ Hosp, S-20502 Malmo, Sweden
[2] Lund Univ, Dept Orthoped Surg, Skane Univ Hosp, S-20502 Malmo, Sweden
[3] Lund Univ, Dept Med Radiat Phys, Skane Univ Hosp, S-20502 Malmo, Sweden
[4] Lund Univ, Dept Radiol, Skane Univ Hosp, S-20502 Malmo, Sweden
[5] Siemens AG, Healthcare Sect, Erlangen, Germany
关键词
Magnetic resonance imaging; Hip; Hip prosthesis; Complications; Metal artifact; ARTHROPLASTY; REDUCTION; IMPLANTS;
D O I
10.1007/s00256-014-1893-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To apply and compare magnetic resonance imaging (MRI) metal artifact reducing sequences (MARS) including subtraction imaging after contrast application in patients with metal-on-metal (MoM) hip prostheses, investigate the prevalence and characteristics of periprosthetic abnormalities, as well as their relation with pain and risk factors. Fifty-two MoM prostheses (35 cases with pain and or risk factors, and 17 controls) in 47 patients were examined in a 1.5-T MR scanner using MARS: turbo spin echo (TSE) with high readout bandwidth with and without view angle tilting (VAT), TSE with VAT and slice encoding for metal artifact correction (SEMAC), short tau inversion recovery (STIR) with matched RF pulses, and post-contrast imaging. The relations of MRI findings to pain and risk factors were analyzed and in five revised hips findings from operation, histology, and MRI were compared. TSE VAT detected the highest number of osteolyses. Soft tissue mass, effusion, and capsular thickening were common, whereas osteolysis in acetabulum and femur were less frequent. Contrast enhancement occurred in bone, synovia, joint capsule, and the periphery of soft tissue mass. There was no significant relation between MRI findings and pain or risk factors. MARS and gadolinium subtraction imaging are useful for evaluation of complications to MoM prosthesis. TSE VAT had the highest sensitivity for osteolysis. Contrast enhancement might indicate activation of aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Pain, small head, or steep prosthesis inclination angle are not useful predictors of periprosthetic abnormalities, and wide indications for MR follow-up are warranted.
引用
收藏
页码:1101 / 1112
页数:12
相关论文
共 21 条
[1]   Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system [J].
Anderson, Helen ;
Toms, Andoni Paul ;
Cahir, John G. ;
Goodwin, Richard W. ;
Wimhurst, James ;
Nolan, John F. .
SKELETAL RADIOLOGY, 2011, 40 (03) :303-307
[2]   Metal-on-Metal Total Hip Arthroplasty: Do Symptoms Correlate with MR Imaging Findings? [J].
Chang, Eric Y. ;
McAnally, James L. ;
Van Horne, James R. ;
Statum, Sheronda ;
Wolfson, Tanya ;
Gamst, Anthony ;
Chung, Christine B. .
RADIOLOGY, 2012, 265 (03) :848-857
[3]   TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[4]   An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27
[5]   METAL SENSITIVITY AS A CAUSE OF BONE NECROSIS AND LOOSENING OF PROSTHESIS IN TOTAL JOINT REPLACEMENT [J].
EVANS, EM ;
FREEMAN, MAR ;
MILLER, AJ ;
VERNONRO.B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1974, B 56 (04) :626-642
[6]  
Hart AJ, 2012, J BONE JOINT SURG AM, V94A, P317, DOI [10.2106/JBJS.K.01266, 10.2106/JBJS.J.01508]
[7]   A MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty [J].
Hauptfleisch, Jennifer ;
Pandit, Hemant ;
Grammatopoulos, George ;
Gill, Harinderjit S. ;
Murray, David W. ;
Ostlere, Simon .
SKELETAL RADIOLOGY, 2012, 41 (02) :149-155
[8]   Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT [J].
Lee, Mi-Jung ;
Kim, Sungjun ;
Lee, Sung-Ah ;
Song, Ho-Taek ;
Huh, Yong-Min ;
Kim, Dae-Hong ;
Han, Seung Hwan ;
Suh, Jin-Suck .
RADIOGRAPHICS, 2007, 27 (03) :791-803
[9]  
Leopold SS, 2011, JBJS ORTHOP HIGHLIGH, V1, pe3
[10]   SEMAC: Slice Encoding for Metal Artifact Correction in MRI [J].
Lu, Wenmiao ;
Pauly, Kim Butts ;
Gold, Garry E. ;
Pauly, John M. ;
Hargreaves, Brian A. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) :66-76