Design and simulation of a new energy conscious system, (ventilation and thermal performance simulation)

被引:8
作者
Gadi, MB [1 ]
机构
[1] Univ Nottingham, Sch Built Environm, Nottingham NG7 2RD, England
关键词
BTS; CATD; cooling; heating; HATD ventilation; wind tunnel;
D O I
10.1016/S0306-2619(99)00119-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results of simulating the ventilation and thermal performance of a new passive cooling and heating system. The new system was integrated into the roof of a typical contemporary North African house, which was modelled and mounted inside a wind tunnel, for natural ventilation simulation. Thermal performance of the new system was simulated using a new computer programme (BTS), developed by the author, Results are presented in terms of indoor temperature and CATD and HATD, which are newly introduced concepts in defining the building cooling and heating loads. (C) 1999 Elsevier Science Ltd. All rights reserved.