Bonding potential of self-adhesive luting agents used at different temperatures to lute composite onlays

被引:35
作者
Cantoro, Amerigo [1 ]
Goracci, Cecilia [1 ]
Carvalho, Carlos Augusto [1 ]
Coniglio, Ivanovic [1 ]
Ferrari, Marco [1 ]
机构
[1] Univ Siena, Dept Dent Mat & Fixed Prosthodont, Policlin Le Scotte, I-53100 Siena, Italy
关键词
Bonding; Self-adhesive resin cements; Dentin; Pre-cure temperature; Pre-heating; RESIN CEMENTS; SMEAR LAYERS; DENTIN; STRENGTH; ENAMEL; PERFORMANCE; THICKNESS; MONOMERS; SYSTEMS;
D O I
10.1016/j.jdent.2009.02.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess whether the bonding potential to dentin of self-adhesive resin cements was affected by their pre-cure temperature. Methods: Composite overlays (Paradigm MZ100, 3M ESPE) were luted on 100 extracted molars with G-Cem (GC Corp.), BisCem (Bisco), Multilink Sprint (Ivoclar Vivadent), SAC-A (Kuraray Co.), XP Bond/Calibra (Detrey Dentsply). The cements were used at pre-cure temperatures that recur in their handling (4 degrees C refrigerator, 24 degrees C room and 37 degrees C intraoral), as well as following pre-heating up to 60 degrees C. Microtensile bond strengths to dentin were measured and compared with statistical tests. Scanning electron microscope observations of cement-dentin interfaces were performed. Results: The bond strength of G-Cem and Calibra was not significantly affected by temperature changes from refrigerator storage to intraoral application. At any assessed pre-cure temperature the total-etch luting agent Calibra achieved a significantly stronger adhesion than the auto-adhesive cements. Limited to null adhesion was yielded by BisCem and SACA. The procedure of 60 degrees C pre-heating, proposed in previous studies for restorative resin composites, was of no use for the tested luting agents. Only the total-etch luting agent Calibra developed a distinct hybrid layer. The self-adhesive cements exhibited a more superficial interaction with dentin. Conclusions: Regardless of the pre-cure temperature, the bonding potential of the self-adhesive resin cements was inferior to that of the total-etch luting agent tested as control. The adhesive properties of the BisCem and SAC-A were extremely scarce. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:454 / 461
页数:8
相关论文
共 30 条
[1]   Bond strength of a new universal self-adhesive resin luting cement to dentin and enamel [J].
Abo-Hamar, SE ;
Hiller, KA ;
Jung, H ;
Federlin, M ;
Friedl, KH ;
Schmalz, G .
CLINICAL ORAL INVESTIGATIONS, 2005, 9 (03) :161-167
[2]  
[Anonymous], 2002, TECHN DAT SHEET ESP
[3]   Effect of temperature on unpolymerized composite resin film thickness [J].
Blalock, John S. ;
Holmes, Robert G. ;
Rueggeberg, Frederick A. .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (06) :424-432
[4]   Effect of pre-cure temperature on the bonding potential of self-etch and self-adhesive resin cements [J].
Cantoro, Amerigo ;
Goracci, Cecilia ;
Papacchini, Federica ;
Mazzitelli, Claudia ;
Fadda, Giovanni Maria ;
Ferrari, Marco .
DENTAL MATERIALS, 2008, 24 (05) :577-583
[5]   Monomer conversion of pre-heated composite [J].
Daronch, M ;
Rueggeberg, FA ;
De Goes, MF .
JOURNAL OF DENTAL RESEARCH, 2005, 84 (07) :663-667
[6]   Bonding of an auto-adhesive luting material to enamel and dentin [J].
De Munck, J ;
Vargas, M ;
Van Landuyt, K ;
Hikita, K ;
Lambrechts, P ;
Van Meerbeek, B .
DENTAL MATERIALS, 2004, 20 (10) :963-971
[7]   Human pulp response to resin cements used to bond inlay restorations [J].
de Souza Costa, Carlos A. ;
Hebling, Josimeri ;
Randall, Ros C. .
DENTAL MATERIALS, 2006, 22 (10) :954-962
[8]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[9]  
FREEDMAN G, 2004, COMPENDIUM, V25, P95
[10]   Chemical analysis and bonding reaction of RelyX Unicem and Bifix composites -: A comparative study [J].
Gerth, Hans U. V. ;
Dammaschke, Till ;
Zuechner, Harald ;
Schaefer, Edgar .
DENTAL MATERIALS, 2006, 22 (10) :934-941