Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis

被引:33
作者
Schrotenboer, Jason
Tsao, Yi-Pin [1 ]
Kinariwala, Vipul [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Cranes Software Inc, Business Dev, Troy, MI USA
关键词
platform switching; implants; numerical analysis; implant abutment; biomechanics; CANCELLOUS BONE; ELASTICITY;
D O I
10.1097/ID.0b013e31819e8c1d
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to investigate, in a model, the interaction phenomena of platform switching on the trans-cortical section of bone adjacent to an endosseous dental implant. Materials: A 2-dimensional finite, element model was fabricated to analyze the bone-implant interactions under masticatory forces. Two abutment diameters, 4.5 mm representing platform switching and 5 mm representing a standard platform, were used in conjunction with a 5-mm diameter fixture. A 100-N static force was applied vertically (90 degrees) and obliquely (15 degrees) to the abutments. All models were obtained using a reverse engineering process with values obtained from other studies to create a hypothetical implant system that demonstrates basic implant features. Results: The standard platform model demonstrated a maximum crestal Von-Mises stress of 28 and 6977 MPa under oblique and vertical loading, respectively. The platform switching model showed 27.43 and 6.502 MPa under oblique and vertical loading, respectively. This implies that a 10% reduction in abutment diameter results in a 2.04% and 6.81% decrease under oblique and vertical loading, respectively, in Von-Mises stress. The distribution pattern of forces was minimally altered between both. abutment models, with a slightly more significant change in the vertical loading scenario. Conclusions: Results from this study showed the reduction of abutment diameter (i.e., platform switching) resulted in a measurable but minimal effect on Von-Mises stress in the crestal region of cortical bone. However, future clinical trials in this area arc, warranted before any firm conclusion is drawn. (Implant Dent 2009;18:260-269)
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [31] The effect of periapical bone defects on stress distribution in teeth with periapical periodontitis: a finite element analysis
    ShuoMin Chen
    ZhangYan Ye
    XinHua Hong
    Liang Chen
    LinMei Wu
    Yilin Wang
    YuGe Chen
    MengHan Wu
    Jun Wang
    QinHui Zhang
    YuTian Wu
    XiaoYu Sun
    Xi Ding
    ShengBin Huang
    ShuFan Zhao
    BMC Oral Health, 23
  • [32] The effect of periapical bone defects on stress distribution in teeth with periapical periodontitis: a finite element analysis
    Chen, Shuomin
    Ye, Zhangyan
    Hong, Xinhua
    Chen, Liang
    Wu, Linmei
    Wang, Yilin
    Chen, Yuge
    Wu, Menghan
    Wang, Jun
    Zhang, Qinhui
    Wu, Yutian
    Sun, Xiaoyu
    Ding, Xi
    Huang, Shengbin
    Zhao, Shufan
    BMC ORAL HEALTH, 2023, 23 (01)
  • [33] Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis
    Alvarez-Arenal, Angel
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Martin-Fernandez, Elena
    Ellacuria-Echebarria, Joseba
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (06) : 419 - 428
  • [34] Finite element simulation of bone remodelling in the human mandible surrounding dental implant
    Lian, Zhiqiang
    Guan, Hong
    Ivanovski, Saso
    Loo, Yew-Chaye
    Johnson, Newell
    Zhang, Hongwu
    ACTA MECHANICA, 2011, 217 (3-4) : 335 - 345
  • [35] Biomechanics study of dental implant-bone system by finite element method
    Iulia Roatesi
    Simona Roatesi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [36] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Oğuz Eraslan
    Özgür İnan
    Clinical Oral Investigations, 2010, 14 : 411 - 416
  • [37] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Eraslan, Oguz
    Inan, Oezguer
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 411 - 416
  • [38] Biomechanics study of dental implant-bone system by finite element method
    Roatesi, Iulia
    Roatesi, Simona
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (06)
  • [39] Platform switching vs platform matching: a radiographic analysis of marginal bone loss
    Montaruli, Graziano
    Maffone, Susanna
    Troiano, Giuseppe
    Tepedino, Michele
    Laurenziello, Michele
    Laino, Luigi
    Lo Muzio, Lorenzo
    DENTAL CADMOS, 2021, 89 (09) : 688 - 696
  • [40] Effect of vertical bone loss on stress distribution at the bone-implant interface around implants of varying diameters-an in silico 3D finite element analysis
    Gupta, Shipra
    Chopra, Priyanka
    Goyal, Parveen
    Jain, Ashish
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 4581 - 4586