Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis

被引:33
|
作者
Schrotenboer, Jason
Tsao, Yi-Pin [1 ]
Kinariwala, Vipul [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Cranes Software Inc, Business Dev, Troy, MI USA
关键词
platform switching; implants; numerical analysis; implant abutment; biomechanics; CANCELLOUS BONE; ELASTICITY;
D O I
10.1097/ID.0b013e31819e8c1d
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to investigate, in a model, the interaction phenomena of platform switching on the trans-cortical section of bone adjacent to an endosseous dental implant. Materials: A 2-dimensional finite, element model was fabricated to analyze the bone-implant interactions under masticatory forces. Two abutment diameters, 4.5 mm representing platform switching and 5 mm representing a standard platform, were used in conjunction with a 5-mm diameter fixture. A 100-N static force was applied vertically (90 degrees) and obliquely (15 degrees) to the abutments. All models were obtained using a reverse engineering process with values obtained from other studies to create a hypothetical implant system that demonstrates basic implant features. Results: The standard platform model demonstrated a maximum crestal Von-Mises stress of 28 and 6977 MPa under oblique and vertical loading, respectively. The platform switching model showed 27.43 and 6.502 MPa under oblique and vertical loading, respectively. This implies that a 10% reduction in abutment diameter results in a 2.04% and 6.81% decrease under oblique and vertical loading, respectively, in Von-Mises stress. The distribution pattern of forces was minimally altered between both. abutment models, with a slightly more significant change in the vertical loading scenario. Conclusions: Results from this study showed the reduction of abutment diameter (i.e., platform switching) resulted in a measurable but minimal effect on Von-Mises stress in the crestal region of cortical bone. However, future clinical trials in this area arc, warranted before any firm conclusion is drawn. (Implant Dent 2009;18:260-269)
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [21] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [22] Finite Element Analysis of a New Dental Implant Design Optimized for the Desirable Stress Distribution in the Surrounding Bone Region
    Paracchini, Luigi
    Barbieri, Christian
    Redaelli, Mattia
    Di Croce, Domenico
    Vincenzi, Corrado
    Guarnieri, Renzo
    PROSTHESIS, 2020, 2 (03): : 225 - 236
  • [23] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648
  • [24] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876
  • [25] Effect of platform switching on peri-implant bone levels: a randomized clinical trial
    Enkling, Norbert
    Joehren, Peter
    Klimberg, Victoria
    Bayer, Stefan
    Mericske-Stern, Regina
    Jepsen, Soren
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (10) : 1185 - 1192
  • [26] Finite Element Stress Analysis of Edentulous Mandibles with Different Bone Types Supporting Multiple-Implant Superstructures
    de Almeida, Erika Oliveira
    Rocha, Eduardo Passos
    Freitas, Amilcar Chagas, Jr.
    Martin, Manoel, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1108 - 1114
  • [27] Platform-Switching to Preserve Peri-Implant Bone: A Meta-Analysis
    Aslam, Ayesha
    Ahmed, Bilal
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (04): : 315 - 319
  • [28] The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis
    Topkaya, Tolga
    Solmaz, Murat Yavuz
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2102 - 2109
  • [29] Biomechanical Evaluation of Platform Switching in Different Implant Protocols: Computed Tomography-Based Three-Dimensional Finite Element Analysis
    Pessoa, Roberto S.
    Vaz, Luis Geraldo
    Marcantonio, Elcio, Jr.
    Vander Sloten, Jos
    Duyck, Joke
    Jaecques, Siegfried V. N.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 911 - 919
  • [30] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368