Objectives: The purpose of this study was to investigate, in a model, the interaction phenomena of platform switching on the trans-cortical section of bone adjacent to an endosseous dental implant. Materials: A 2-dimensional finite, element model was fabricated to analyze the bone-implant interactions under masticatory forces. Two abutment diameters, 4.5 mm representing platform switching and 5 mm representing a standard platform, were used in conjunction with a 5-mm diameter fixture. A 100-N static force was applied vertically (90 degrees) and obliquely (15 degrees) to the abutments. All models were obtained using a reverse engineering process with values obtained from other studies to create a hypothetical implant system that demonstrates basic implant features. Results: The standard platform model demonstrated a maximum crestal Von-Mises stress of 28 and 6977 MPa under oblique and vertical loading, respectively. The platform switching model showed 27.43 and 6.502 MPa under oblique and vertical loading, respectively. This implies that a 10% reduction in abutment diameter results in a 2.04% and 6.81% decrease under oblique and vertical loading, respectively, in Von-Mises stress. The distribution pattern of forces was minimally altered between both. abutment models, with a slightly more significant change in the vertical loading scenario. Conclusions: Results from this study showed the reduction of abutment diameter (i.e., platform switching) resulted in a measurable but minimal effect on Von-Mises stress in the crestal region of cortical bone. However, future clinical trials in this area arc, warranted before any firm conclusion is drawn. (Implant Dent 2009;18:260-269)
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [1] The Effect of Platform Switching on Stress in Peri-implant Bone in a Condition of Marginal Bone Resorption: A Three-Dimensional Finite Element Analysis
    Xia, Haibin
    Wang, Min
    Ma, Li
    Zhou, Yi
    Li, Zhiyong
    Wang, Yining
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : E122 - E127
  • [2] Effect of Microthreads and Platform Switching on Crestal Bone Stress Levels: A Finite Element Analysis
    Schrotenboer, Jason
    Tsao, Yi-Pin
    Kinariwala, Vipul
    Wang, Hom-Lay
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (11) : 2166 - 2172
  • [3] Biomechanical Effect of Platform Switching in Implant Dentistry: A Three-Dimensional Finite Element Analysis
    Chang, Chih-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (02) : 295 - 304
  • [4] Influence of Fine Threads and Platform-Switching on Crestal Bone Stress Around Implant-A Three-Dimensional Finite Element Analysis
    Khurana, Pardeep
    Sharma, Arun
    Sodhi, Kiranmeet Kaur
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) : 697 - 703
  • [5] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [6] Bone Strain and Interfacial Sliding Analyses of Platform Switching and Implant Diameter on an Immediately Loaded Implant: Experimental and Three-Dimensional Finite Element Analyses
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Lin, Dan-Jae
    Shen, Yen-Wen
    Huang, Heng-Li
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (07) : 1125 - 1132
  • [7] Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis
    Tabata, Lucas Fernando
    Assuncao, Wirley Goncalves
    Ricardo Barao, Valentim Adelino
    Capello de Sousa, Edson Antonio
    Gomes, Erica Alves
    Delben, Juliana Aparecida
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (01) : 182 - 187
  • [8] The Effect of Implant Thread Design on Stress Distribution in Anisotropic Bone with Different Osseointegration Conditions: A Finite Element Analysis
    Mosavar, Alireza
    Ziaei, Alireza
    Kadkhodaei, Mahmoud
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) : 1317 - 1326
  • [9] Effect of crown-to-implant ratio on peri-implant stress: A finite element analysis
    Verri, Fellippo Ramos
    de Souza Batista, Victor Eduardo
    Santiago, Joel Ferreira, Jr.
    de Faria Almeida, Daniel Augusto
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 234 - 240
  • [10] The Effect of Placement Depth of Platform- Switched Implants on Periimplant Cortical Bone Stress: A 3-Dimensional Finite Element Analysis
    Rismanchian, Mansour
    Askari, Navid
    Shafiei, Soufia
    IMPLANT DENTISTRY, 2013, 22 (02) : 165 - 169