COMPARATIVE MECHANICAL AND CORROSION STUDIES ON MAGNESIUM, ZINC AND IRON ALLOYS AS BIODEGRADABLE METALS

被引:60
作者
Vojtech, Dalibor [1 ]
Kubasek, Jiri [1 ]
Capek, Jaroslav [1 ]
Pospisilova, Iva [1 ]
机构
[1] Inst Chem Technol, Dept Met & Corros Engn, Tech 5, CR-16628 Prague 6, Czech Republic
来源
MATERIALI IN TEHNOLOGIJE | 2015年 / 49卷 / 06期
关键词
biodegradable metal; magnesium; zinc; iron; mechanical properties; corrosion; IMPLANTS;
D O I
10.17222/mit.2014.129
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, selected magnesium, zinc and iron biodegradable alloys were studied as prospective biomaterials for temporary medical implants like stents and fixation devices for fractured bones. Mechanical properties of the alloys were characterized with hardness and tensile tests. In-vitro corrosion behavior was studied using immersion tests in a simulated physiological solution (SPS, 9 g/L NaCl) to roughly estimate the in-vivo biodegradation rates of implants. It was found that the Mg and Zn alloys were limited by a tensile strength of 370 MPa, while the tensile strength of the Fe alloys achieved 530 MPa. The main advantage of the Mg alloys is that their Young's modulus of elasticity is similar to that of the human bone. However, the corrosion tests revealed that the Mg-based alloys showed the highest corrosion rates in the SPS, ranging between 0.6 mm and 4.0 mm per year, which is above the tolerable degradation rates of implants. The corrosion rates of the Zn alloys were between 0.3 mm and 0.6 mm per year and the slowest corrosion rates of approximately 0.2 mm per year were observed for the Fe alloys. The results indicate that all three kinds of alloys meet the mechanical requirements for the load-bearing implants. From the corrosion-behavior point of view, the Zn-and Fe-based "slowly corroding" alloys appear as promising alternatives to the Mg-based alloys.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 22 条
[1]   Corrosion mechanism applicable to biodegradable magnesium implants [J].
Atrens, Andrej ;
Liu, Ming ;
Abidin, Nor Ishida Zainal .
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2011, 176 (20) :1609-1636
[2]   Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
ADVANCED MATERIALS, 2013, 25 (18) :2577-2582
[3]   Recent advances on the development of magnesium alloys for biodegradable implants [J].
Chen, Yongjun ;
Xu, Zhigang ;
Smith, Christopher ;
Sankar, Jag .
ACTA BIOMATERIALIA, 2014, 10 (11) :4561-4573
[4]  
Davis J, 2003, HDB MAT MED DEVICES, Vfirst, DOI [10.1361/hmmd2003p001, DOI 10.1361/HMMD2003P001]
[5]   ZINC TOXICITY [J].
FOSMIRE, GJ .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (02) :225-227
[6]   Developments in metallic biodegradable stents [J].
Hermawan, H. ;
Dube, D. ;
Mantovani, D. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1693-1697
[7]   Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities [J].
Moravej, Maryam ;
Mantovani, Diego .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2011, 12 (07) :4250-4270
[8]   Magnesium and its alloys as orthopedic biomaterials: A review [J].
Staiger, MP ;
Pietak, AM ;
Huadmai, J ;
Dias, G .
BIOMATERIALS, 2006, 27 (09) :1728-1734
[9]  
Talbot D.E.J., 2007, Corrosion Science and Technology
[10]   Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation [J].
Vojtech, D. ;
Kubasek, J. ;
Serak, J. ;
Novak, P. .
ACTA BIOMATERIALIA, 2011, 7 (09) :3515-3522