Nature-Inspired Flow Patterns for Active Magnetic Regenerators Assessed Using a 1D AMR Model

被引:14
作者
Navickaite, Kristina [1 ]
Bahl, Christian [1 ]
Engelbrecht, Kurt [1 ]
机构
[1] Tech Univ Denmark, Dept Energy Convers & Storage, Roskilde, Denmark
关键词
magnetocaloric heat pump; active magnetic regenerators; biomimetics; AMR modeling; solid state cooling; MAGNETOCALORIC HEAT-PUMP; PACKED-BED; REFRIGERATION; PERFORMANCE; OPTIMIZATION; DESIGN; ENDOTHERMY; GEOMETRIES; EVOLUTION; LOSSES;
D O I
10.3389/fenrg.2019.00068
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel flow structure of a solid active magnetic regenerator is proposed in this paper. The numerical performances of two nature-inspired flow geometries, based on double corrugated tubes with an elliptical cross-section, are compared to the performance of conventional flow structures for Active Magnetic Regeneration (AMR) applications, namely, packed spheres and a cylindrical micro-channel matrix. The numerical performance of all the geometries is analyzed in terms of cooling power and coefficient of performance. Regenerators with various porosities and two different hydraulic diameters of the flow channels are evaluated varying utilization at fixed temperature spans between the hot and cold reservoirs. The selection of the regenerator geometry is based on two actual AMR machines. The numerical results demonstrate that a suitably optimized AMR geometry with a double corrugated flow pattern provides the same or higher efficiency at higher porosity compared to conventional AMR flow geometries. These findings suggest that the magnetocaloric material used to construct AMR beds can be exploited more efficiently and at a lower investment cost of an AMR device when suitable double corrugated flow pattern is used.
引用
收藏
页数:17
相关论文
共 56 条
  • [1] [Anonymous], 2014, Energy Savings Potential and RDD Opportunities for Non-Vapor-Compression HVAC Technologies
  • [2] A rotary permanent magnet magnetic refrigerator based on AMR cycle
    Aprea, C.
    Cardillo, G.
    Greco, A.
    Maiorino, A.
    Masselli, C.
    [J]. APPLIED THERMAL ENGINEERING, 2016, 101 : 699 - 703
  • [3] Modelling an active magnetic refrigeration system: A comparison with different models of incompressible flow through a packed bed
    Aprea, C.
    Greco, A.
    Maiorino, A.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 36 : 296 - 306
  • [4] A comparison between experimental and 2D numerical results of a packed-bed active magnetic regenerator
    Aprea, Ciro
    Cardillo, Gerardo
    Greco, Adriana
    Maiorino, Angelo
    Masselli, Claudia
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 376 - 383
  • [5] Design improvements of a permanent magnet active magnetic refrigerator
    Arnold, D. S.
    Tura, A.
    Ruebsaat-Trott, A.
    Rowe, A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 37 : 99 - 105
  • [6] Operational test of bonded magnetocaloric plates
    Bahl, Christian R. H.
    Navickaite, Kristina
    Bez, Henrique Neves
    Lei, Tian
    Engelbrecht, Kurt
    Bjork, Rasmus
    Li, Ke
    Li, Zhenxing
    Shen, Jun
    Dai, Wei
    Jia, Jichen
    Wu, Yuanyuan
    Long, Yi
    Hu, Fengxia
    Shen, Baogen
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 76 : 245 - 251
  • [7] Advanced materials for magnetic cooling: Fundamentals and practical aspects
    Balli, M.
    Jandl, S.
    Fournier, P.
    Kedous-Lebouc, A.
    [J]. APPLIED PHYSICS REVIEWS, 2017, 4 (02):
  • [8] Model of a porous regenerator used for magnetic refrigeration at room temperature
    Bouchard, Jonathan
    Nesreddine, Hakim
    Galanis, Nicolas
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (5-6) : 1223 - 1229
  • [9] Brown G. V, 1981, USA Patent, Patent No. 4392356
  • [10] MAGNETIC HEAT PUMPING NEAR ROOM-TEMPERATURE
    BROWN, GV
    [J]. JOURNAL OF APPLIED PHYSICS, 1976, 47 (08) : 3673 - 3680