Responses of self-anchored suspension bridge to sudden breakage of hangers

被引:12
作者
Qiu, Wenliang [1 ]
Jiang, Meng [1 ]
Zhang, Zhe [1 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China
基金
中国国家自然科学基金;
关键词
self-anchored suspension bridge; sudden breakage of hanger; responses; static analysis; dynamic analysis;
D O I
10.12989/sem.2014.50.2.241
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of a concrete self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger has significant effects on tensions of the hangers next to the broken hanger, bending and torsion moments of the girder, moments of the towers and reaction forces of the bearings. The results obtained from dynamic analysis method are very different from those obtained from static analysis method. The maximum tension of hanger produced by breakage of a hanger exceeds 2.2 times of its initial value, the maximum dynamic amplification factor reaches 2.54, which is larger than the value of 2.0 recommended for cable-stayed bridge in PTI codes. If two adjacent hangers on the same side of bridge break one after another, the maximum tension of other hangers exceeds 3.0 times of its initial value. If the safety factor adopted to design hanger is too small, or the hangers have been exposed to corrosion, the bridge may collapse due to breakage of two adjacent hangers.
引用
收藏
页码:241 / 255
页数:15
相关论文
共 15 条
[1]   Comparison of various procedures for progressive collapse analysis of cable-stayed bridges [J].
Cai, Jian-guo ;
Xu, Yi-xiang ;
Zhuang, Li-ping ;
Feng, Jian ;
Zhang, Jin .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2012, 13 (05) :323-334
[2]  
Kao CS, 2012, J MAR SCI TECH-TAIW, V20, P18
[3]  
Ministry of Transport of P.R. China, 2002, DES SPEC HIGHW SUSP
[4]   Numerical and experimental study on the interaction cable structure during the failure of a stay in a cable stayed bridge [J].
Mozos, C. M. ;
Aparicio, A. C. .
ENGINEERING STRUCTURES, 2011, 33 (08) :2330-2341
[5]   Parametric study on the dynamic response of cable stayed bridges to the sudden failure of a stay, Part I: Bending moment acting on the deck [J].
Mozos, C. M. ;
Aparicio, A. C. .
ENGINEERING STRUCTURES, 2010, 32 (10) :3288-3300
[6]   Parametric study on the dynamic response of cable stayed bridges to the sudden failure of a stay, Part II: Bending moment acting on the pylons and stress on the stays [J].
Mozos, C. M. ;
Aparicio, A. C. .
ENGINEERING STRUCTURES, 2010, 32 (10) :3301-3312
[7]  
Post-Tensioning Institute (PTI), 2007, REC STAY CABLE DES
[8]  
Qiu Wen-liang, 2009, Journal of Harbin Institute of Technology, V41, P128
[9]   Dynamic amplification factors in cable-stayed structures [J].
Ruiz-Teran, A. M. ;
Aparicio, A. C. .
JOURNAL OF SOUND AND VIBRATION, 2007, 300 (1-2) :197-216
[10]   Response of under-deck cable-stayed bridges to the accidental breakage of stay cables [J].
Ruiz-Teran, A. M. ;
Aparicio, A. C. .
ENGINEERING STRUCTURES, 2009, 31 (07) :1425-1434