Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [41] Prognostic Value of Left Ventricular Dyssynchrony Assessed with Nuclear Cardiology in Patients with Known or Suspected Stable Coronary Artery Disease with Preserved Left Ventricular Ejection Fraction
    Hatta, Takumi
    Yoda, Shunichi
    Hayase, Misa
    Monno, Koyuru
    Hori, Yusuke
    Fujito, Hidesato
    Suzuki, Yasuyuki
    Matsumoto, Naoya
    Okumura, Yasuo
    INTERNATIONAL HEART JOURNAL, 2020, 61 (04) : 685 - 694
  • [42] Deterioration of left ventricular ejection fraction and contraction synchrony during right ventricular pacing in patients with left bundle branch block
    Friehling, Mati
    Ludwig, Daniel R.
    Dunn, Michael
    Siddoway, Donald
    Soman, Prem
    Schwartzman, David
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 830 - 834
  • [43] Effect of alcohol septal ablation in patients with hypertrophic cardiomyopathy on left-ventricular mechanical dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging
    Chen, Ji
    Nagaraj, Hosakote
    Bhambhani, Pradeep
    Kliner, Dustin E.
    Soman, Prem
    Garcia, Ernest V.
    Heo, Jaekyeong
    Iskandrian, Ami E.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06) : 1375 - 1384
  • [44] Left ventricular systolic and diastolic dyssynchrony assessed by phase analysis of gated SPECT myocardial perfusion imaging: a comparison with speckle tracking echocardiography
    Hsu, Tang-Ho
    Huang, Wen-Sheng
    Chen, Chien-Cheng
    Hung, Guang-Uei
    Chen, Tsai-Chou
    Kao, Chia-Hung
    Chen, Ji
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (08) : 764 - 771
  • [45] Extracellular volume fraction assessed using cardiovascular magnetic resonance can predict improvement in left ventricular ejection fraction in patients with dilated cardiomyopathy
    Inui, Keisuke
    Asai, Kuniya
    Tachi, Masaki
    Yoshinaga, Aya
    Izumi, Yuki
    Kubota, Yoshiaki
    Murai, Koji
    Tsukada, Yayoi Tetsuou
    Amano, Yasuo
    Kumita, Shinichiro
    Shimizu, Wataru
    HEART AND VESSELS, 2018, 33 (10) : 1195 - 1203
  • [46] Comparison of software programs for the assessment of left ventricular ejection fraction using 99mTc-tetrofosmin-gated SPECT/CT: correlation with equilibrium radionuclide ventriculography in the Indian population
    Ballal, Sanjana
    Patel, Chetan D.
    Singla, Suhas
    Sharma, Punit
    Narang, Rajiv
    Sharma, Gautam
    Malhotra, Arun
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1160 - 1168
  • [47] Assessment of left ventricular ejection fraction by four different methods using 99mTc tetrofosmin gated SPECT in patients with small hearts:: correlation with gated blood pool
    Khalil, Magdy M.
    Elgazzar, Abdelhamid
    Khalil, Wafaa
    Omar, Abdelmoniem
    Ziada, Gaber
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (10) : 883 - 891
  • [48] Myocardial perfusion and left ventricular function indices assessed by gated myocardial perfusion SPECT in methamphetamine abusers
    Dadpour, Bita
    Kakhki, Vahid R. Dabbagh
    Afshari, Reza
    Dorri-giv, Masoumeh
    Mohajeri, Seyed A. R.
    Ghahremani, Somayeh
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (12) : 1302 - 1305
  • [49] Evaluation of Left and Right Ventricular Ejection Fraction and Volumes from Gated Blood-Pool SPECT in Patients with Dilated Cardiomyopathy: Comparison with Cardiac MRI
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Zhao, Shi-Hua
    Yang, Min-Fu
    Guo, Feng
    Wang, Dao-Yu
    Wei, Hong-Xing
    Chu, Ke-Wei
    He, Zuo-Xiang
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 584 - 591
  • [50] Underestimation of the ejection fraction using the quantitative gated SPECT for patients with myocardial hypertrophy
    Yamaguchi, Hidenori
    Toba, Masahiro
    Amano, Yasuo
    Ishihara, Keiichi
    Mizuno, Kyoichi
    Kumita, Shin-ichiro
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (06) : 502 - 507