Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
|
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [21] Comparison of prone and supine determination of left ventricular ejection fraction measured by gated myocardial SPECT.
    Papathanassiou, D
    Liehn, JC
    Wampach, H
    Perault, C
    Ouzan, J
    Pron, T
    Dedienne, B
    Bouchard, A
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1997, 21 (8-9): : 458 - 461
  • [22] Impact of a decrease in recorded counts on the left ventricular ejection fraction measurement from the D-SPECT camera
    Tissot, H.
    Morel, O.
    Imbert, L.
    Roch, V.
    Claudin, M.
    Perrin, M.
    Verger, A.
    Karcher, G.
    Marie, P. -Y.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2017, 41 (02): : 83 - 92
  • [23] Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
    Vidigal Ferreira, Maria Joao
    Silva, Rodolfo
    Cabanelas, Nuno
    Cunha, Maria Joao
    Ramos, Domingos
    Albuquerque, Anabela
    Teixeira, Rogerio
    Moreira, Ana Paula
    Costa, Gracinda
    Lima, Joao
    Providencia, Luis Augusto
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (05) : 387 - 394
  • [24] Clinical relevance of left ventricular volumes and function assessed by gated SPECT in paediatric patients
    El-Maghraby, TAF
    Abd El-Rahman, N
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (02) : 127 - 134
  • [25] Clinical relevance of left ventricular volumes and function assessed by gated SPECT in paediatric patients
    Tarek Abdel-Fattah El-Maghraby
    Naglaa Abd El-Rahman
    The International Journal of Cardiovascular Imaging, 2004, 20 : 127 - 134
  • [26] A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts
    Mazinani, Mahdi
    Tajik-Mansoury, Mohammad Ali
    Sabour, Mahsa
    Jadidi, Majid
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (06) : 2079 - 2084
  • [27] Comparison of totally automated and manual processing for calculation of left ventricular volumes and ejection fraction using gated myocardial perfusion SPECT
    Al-Shammari, Amirah Fahad
    Afzal, Uzma
    CARDIOMETRY, 2022, (22): : 136 - 142
  • [28] Quantification of left ventricular volumes and ejection fraction from 16- and rebinned 8-frame gated 99mTc-tetrofosmin SPECT
    Schaefer, W. M.
    Kaiser, H-J.
    Kuehl, H.
    Koch, K-C.
    Nowak, B.
    Buell, U.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (01): : 22 - 28
  • [29] Effect of gender on cardiovascular risk stratification with ECG gated SPECT left ventricular volume indices and ejection fraction
    Orren Wexler
    Scott R. Yoder
    Jessica L Elder
    Maria L. Mackin
    Leway Chen
    Lonnie Mixon
    Ronald G. Schwartz
    Journal of Nuclear Cardiology, 2009, 16 : 28 - 37
  • [30] Prognostic value of the left ventricular ejection fraction reserve acquired by gated myocardial perfusion SPECT in patients with CAD and reduced stress LVEF
    Zhang, Shuang
    Meng, Jingjing
    Zhou, Yihan
    Lv, Lijun
    Zhang, Xiaoli
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11