Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
|
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [1] Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging
    Lucia Leva
    Roberta Matheoud
    Gianmauro Sacchetti
    Alessandro Carriero
    Marco Brambilla
    Journal of Nuclear Cardiology, 2020, 27 : 1714 - 1724
  • [2] CMR validation of left ventricular volumes and ejection fraction measured by the IQ-SPECT system in patients with small heart size
    Wei, Hua
    Wu, Jiaojiao
    Han, Ke
    Hu, Guang
    Wang, Hongliang
    Guo, Xiaoshan
    Liu, Haiyan
    Wu, Zhifang
    Li, Sijin
    EJNMMI RESEARCH, 2023, 13 (01)
  • [3] Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR
    Hippelainen, Eero
    Makela, Teemu
    Kaasalainen, Touko
    Kaleva, Erna
    EJNMMI PHYSICS, 2017, 4
  • [4] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Wang, Feng
    Zhang, Jian
    Fang, Wei
    Zhao, Shi-Hua
    Lu, Min-Jie
    He, Zuo-Xiang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1611 - 1621
  • [5] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    Marcassa, C.
    Giubbini, R.
    Acampa, W.
    Cittanti, C.
    Djepaxhija, O.
    Gimelli, A.
    Kokomani, A.
    Medolago, G.
    Milan, E.
    Sciagra, R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1292 - 1301
  • [6] Characteristics of iodine-123 IQ-SPECT/CT imaging compared with conventional SPECT/CT
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Yoneyama, Hiroto
    Konishi, Takahiro
    Matsuo, Shinro
    Nakajima, Kenichi
    ANNALS OF NUCLEAR MEDICINE, 2019, 33 (02) : 103 - 111
  • [7] Assessment of left ventricular ejection fraction with cardiofocal collimators: Comparison between IQ-SPECT, planar equilibrium radionuclide angiography, and cardiac magnetic resonance
    Pelletier-Galarneau, Matthieu
    Finnerty, Vincent
    Tan, Stephanie
    Authier, Sebastien
    Gregoire, Jean
    Harel, Francois
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (06) : 1857 - 1864
  • [8] A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT
    Kliner, Dustin
    Wang, Li
    Winger, Daniel
    Follansbee, William P.
    Soman, Prem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (06) : 1237 - 1243
  • [9] Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography
    Acampa, Wanda
    Caprio, Maria Grazia
    Nicolai, Emanuele
    Liuzzi, Raffaele
    De Luca, Serena
    Capasso, Enza
    Luongo, Luca
    Petretta, Mario
    Cuocolo, Alberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (02) : 349 - 356
  • [10] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    C. Marcassa
    R. Giubbini
    W. Acampa
    C. Cittanti
    O. Djepaxhija
    A. Gimelli
    A. Kokomani
    G. Medolago
    E. Milan
    R. Sciagrà
    Journal of Nuclear Cardiology, 2017, 24 : 1292 - 1301