Limited sample recovery in coupled methods of high-performance liquid chromatography of synthetic polymers

被引:25
|
作者
Berek, D. [1 ]
Russ, A. [1 ]
机构
[1] Slovak Acad Sci, Inst Polymer, Lab Liquid Chromatog, SK-84236 Bratislava, Slovakia
关键词
D O I
10.2478/s11696-006-0044-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Complex polymer systems, which exhibit multiple distributions in their molecular parameters can be characterized by coupled liquid chromatographic methods. The latter combine entropic (exclusion) and enthalpic (interaction) retention mechanisms. However, recent experimental results suggest that some coupled liquid chromatographic methods may suffer from incomplete sample recovery. This refers, for example, to liquid chromatography under critical conditions of enthalpic interactions and to eluent gradient liquid chromatography. Sample recovery in both latter methods was investigated for selected model systems applying adsorption retention mechanism. Reduced sample recovery was confirmed for both methods. It was revealed that even very high final strength of mobile phase may be insufficient for complete elution of polymer samples in eluent gradient polymer liquid chromatography.
引用
收藏
页码:249 / 252
页数:4
相关论文
共 50 条
  • [41] A NEW VALVE FOR ZONE-ELECTROPHORETIC SAMPLE TREATMENT COUPLED ONLINE WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEBETS, AJJ
    HUPE, KP
    BRINKMAN, UAT
    KOK, WT
    CHROMATOGRAPHIA, 1990, 29 (5-6) : 217 - 222
  • [42] Determination of Pharmaceuticals by Dynamic Cell Membrane Chromatography Coupled with High-Performance Liquid Chromatography
    Deng, Binge
    Gan, Yuan
    Zhang, Meng
    Ye, Liming
    ANALYTICAL LETTERS, 2018, 51 (08) : 1109 - 1121
  • [43] LIQUID SAMPLE LOOP GEOMETRY FOR TRACE ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH LARGE SAMPLE VOLUMES
    ZEHNER, JM
    SIMONAITIS, RA
    ANALYTICAL CHEMISTRY, 1978, 50 (07) : 1013 - 1014
  • [44] High-performance liquid chromatography coupled on-line with high resolution gas chromatography - State of the art
    Mondello, L
    Dugo, P
    Dugo, G
    Lewis, AC
    Bartle, KD
    JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) : 373 - 390
  • [45] Sample size and retention values in gradient liquid chromatography of synthetic polymers
    Glockner, G
    Engelhardt, H
    Wolf, D
    Schultz, R
    CHROMATOGRAPHIA, 1996, 42 (3-4) : 185 - 190
  • [46] HIGH-PERFORMANCE LIQUID LIQUID-CHROMATOGRAPHY
    CROMBEEN, JP
    HEEMSTRA, S
    KRAAK, JC
    JOURNAL OF CHROMATOGRAPHY, 1984, 286 (MAR): : 119 - 129
  • [47] INACCURACIES DUE TO SAMPLE SOLVENT INTERACTIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    INMAN, EL
    MALONEY, AM
    RICKARD, EC
    JOURNAL OF CHROMATOGRAPHY, 1989, 465 (02): : 201 - 213
  • [48] Automated determination of polyamines by high-performance liquid chromatography with simple sample preparation
    vanEijk, HMH
    Rooyakkers, DR
    Deutz, NEP
    JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) : 115 - 120
  • [49] VARIABLE-VOLUME SAMPLE VALVE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MINARIK, M
    POPL, M
    MOSTECKY, J
    JOURNAL OF CHROMATOGRAPHY, 1981, 208 (01): : 67 - 70
  • [50] High-performance liquid chromatography on silica modified with temperature-responsive polymers
    Song, YX
    Wang, JQ
    Su, ZX
    Chen, DY
    CHROMATOGRAPHIA, 2001, 54 (3-4) : 208 - 212