Associations between HbA1c and continuous glucose monitoring-derived glycaemic variables

被引:50
|
作者
Hirsch, I. B. [1 ]
Welsh, J. B. [2 ]
Calhoun, P. [2 ,3 ]
Puhr, S. [2 ]
Walker, T. C. [2 ]
Price, D. A. [2 ]
机构
[1] Univ Washington, Sch Med, Seattle, WA USA
[2] Dexcom Inc, San Diego, CA 92121 USA
[3] Jaeb Ctr Hlth Res, Tampa, FL USA
关键词
DAILY INSULIN INJECTIONS; SEVERE HYPOGLYCEMIA; DIABETIC-KETOACIDOSIS; ADULTS; MULTICENTER; CONSENSUS; DIAMOND;
D O I
10.1111/dme.14065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To identify clinically useful associations between HbA(1c) levels and various continuous glucose monitoring-derived metrics. Methods We retrospectively analysed end-of-study HbA(1c) levels and >2 weeks of continuous glucose monitoring data collected from 530 adults with Type 1 diabetes or insulin-requiring Type 2 diabetes during four randomized trials. Each trial lasted >= 24 weeks and provided central laboratory end-of-study HbA(1c) levels and continuous glucose monitoring data from the preceding 3 months. Participants were assigned to groups based on either HbA(1c) levels or continuous glucose monitoring-derived glucose values. Results HbA(1c) was strongly correlated with mean glucose value (r=0.80), time spent with glucose values in the 3.9-10.0 mmol/l range (time in range; r=-0.75) and percentage of glucose values >13.9 mmol/l (r=0.72), but was weakly correlated with the percentage of glucose values <3.9 mmol/l (r=-0.39) or <3.0 mmol/l (r=-0.21). The median percentage of glucose values <3.0 mmol/l was <1.2% (<20 min/day) for all HbA(1c)-based groups, but the median percentage of values >13.9 mmol/l varied from 2.5% (0.6 h/day) to 27.8% (6.7 h/day) in the lowest and highest HbA(1c) groups, respectively. More than 90% of participants with either 13.9 mmol/l, mean glucose <7.8 mmol/l, or time in range >80% had HbA(1c) levels <= 53 mmol/mol (<= 7.0%). For participants with HbA(1c) >= 64 mmol/mol (>= 8.0%), the median time in range was 44%, with 90% of participants having a time in range of <59%. Conclusions The associations shown in the present study suggest that continuous glucose monitoring-derived metrics may help guide diabetes therapy intensification efforts in an HbA(1c)-independent manner.
引用
收藏
页码:1637 / 1642
页数:6
相关论文
共 50 条
  • [21] HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes
    Stimson, Roland H.
    Dover, Anna R.
    Ritchie, Stuart A.
    Wright, Rohana J.
    McKnight, John A.
    Zammitt, Nicola N.
    Gibb, Fraser W.
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (01)
  • [22] Racial and Ethnic Differences in the Relationship between HbA1c and Blood Glucose: Implications for the Diagnosis of Diabetes
    Herman, William H.
    Cohen, Robert M.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2012, 97 (04) : 1067 - 1072
  • [23] Prepregnancy care in women with type 1 diabetes improves HbA1c and glucose variability without worsening hypoglycaemia time and awareness Glycaemic variability during prepregnancy care
    Perea, Veronica
    Gimenez, Marga
    Amor, Antonio J.
    Bellart, Jordi
    Conget, Ignacio
    Vinagre, Irene
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 154 : 75 - 81
  • [24] Associations between clinical and psychosocial factors and HbA1c in adult insulin pump users with type 1 diabetes
    Schmidt, Signe
    Madsen, Kristoffer Panduro
    Pedersen-Bjergaard, Ulrik
    Rytter, Karen
    Hommel, Eva
    Cleal, Bryan
    Willaing, Ingrid
    Andersen, Henrik Ullits
    Norgaard, Kirsten
    ACTA DIABETOLOGICA, 2023, 60 (08) : 1089 - 1097
  • [25] Associations Between the Time in Hypoglycemia and Hypoglycemia Awareness Status in Type 1 Diabetes Patients Using Continuous Glucose Monitoring Systems
    Lin, Yu Kuei
    Groat, Danielle
    Chan, Owen
    Hung, Man
    Sharma, Anu
    Varner, Michael W.
    Gouripeddi, Ramkiran
    Facelli, Julio C.
    Fisher, Simon J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 787 - 793
  • [26] Evaluation of glycemia risk index and continuous glucose monitoring-derived metrics in type 1 diabetes: a real-world observational study
    Al Hayek, Ayman
    Al Mashali, Malak
    Al Dawish, Mohamed A.
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2025, 24 (01)
  • [27] Alarm Settings of Continuous Glucose Monitoring Systems and Associations to Glucose Outcomes in Type 1 Diabetes
    Lin, Yu Kuei
    Groat, Danielle
    Chan, Owen
    Hung, Man
    Sharma, Anu
    Varner, Michael W.
    Gouripeddi, Ramkiran
    Facelli, Julio C.
    Fisher, Simon J.
    JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (01)
  • [28] HbA1c and hypoglycaemia outcomes for people with type 1 diabetes due to the introduction of a single-day structured education programme and flash glucose monitoring
    Garden, Gillian L.
    Hunt, David W.
    Mackie, Karen
    Tuthill, Beverly
    Griffith, Helen
    Russell-Jones, David L.
    Herring, Roselle A.
    BRITISH JOURNAL OF DIABETES, 2021, 21 (01): : 84 - +
  • [29] Improving HbA1c Control in Type 1 or Type 2 Diabetes Using Flash Glucose Monitoring: A Retrospective Observational Analysis in Two German Centres
    Rose, Ludger
    Klausmann, Gerhard
    Seibold, Alexander
    DIABETES THERAPY, 2021, 12 (01) : 363 - 372
  • [30] Time in range (TIR) vs. glycated hemoglobin type A1c (HbA1c): a patient-centered approach Continuous glucose monitoring metrics in daily practice
    Harer, Clemens
    Mader, Julia K.
    DIABETOLOGIE, 2022, 18 (08): : 894 - 901