Influence of Frequency Bands in EEG Signal to Predict User Intent

被引:0
作者
Schreiber, Melynda A. [1 ]
Trkov, Mitja [1 ]
Merryweather, Andrew [1 ]
机构
[1] Univ Utah, Mech Engn Dept, Salt Lake City, UT 84112 USA
来源
2019 9TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER) | 2019年
关键词
CLASSIFICATION;
D O I
10.1109/ner.2019.8716947
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Decoding motor user intent using electroencephalography (EEG) sensors may aid individuals with limited upper extremity mobility. Researchers have successfully used Filter Bank Common Spatial Pattern (FBCSP) and Linear Discriminant Analysis (LDA) to predict user intent from EEG. Frequency bands between 8 to 40 Hz, with 4 Hz intervals are used as inputs to FBCSP classification. While this range includes the commonly used alpha (8-13 Hz) and beta (16-24 Hz) frequency bands, it excludes the delta band (0.3-3 Hz). The delta band has been shown to contain information regarding user intent. This paper investigates the accuracy of predicting user intent to reach and lift when modifying FBCSP to include combinations of alpha, beta and delta bands. This comparison was performed for clinical (32-electrodes) and commercial (12-electrodes) EEG electrode configurations using the WAY-EEG-GAL dataset. The simulated commercial configuration placement mimicked those from the Emotiv Epoc+. We predicted intent to reach (HandStart) and lift a block (LiftOff) by comparing the EEG signal to rest conditions. Intent classification accuracy is the accuracy to predict the future event before the event occurs. Maximum classification accuracy is the maximum accuracy to predict the event during the region of interest (-2.5, -2.0 sec.). Intent classification accuracy of 80.2% and 76.7% were achieved for the clinical and commercial configurations, respectively. Maximum classification accuracy of 85.9% and 83.0% were achieved for the clinical and commercial configuration, respectively. The combination of all three bands outperformed alpha-beta-only and delta-only by 0.9% and 9.9% for the clinical and 4.0% and 4.3% for the commercial for maximum classification accuracy. Using the combination of bands resulted in a maximum classification above 80% for the commercial configuration. These results suggest that including the delta frequency band can help improve the accuracy of user intent in clinical and commercial headsets.
引用
收藏
页码:1126 / 1129
页数:4
相关论文
共 17 条
[1]  
ANG KK, 2008, IEEE IJCNN, P2390, DOI DOI 10.1109/IJCNN.2008.4634130
[2]  
[Anonymous], GRASP LIFT EEG DET
[3]  
[Anonymous], 2014, Front. Neurosci., DOI [DOI 10.3389/FNINS.2014.00222, 10.3389/fnins.2014.00222]
[4]   Validation of the Emotiv EPOC® EEG gaming systemfor measuring research quality auditory ERPs [J].
Badcock, Nicholas A. ;
Mousikou, Petroula ;
Mahajan, Yatin ;
de Lissa, Peter ;
Thie, Johnson ;
McArthur, Genevieve .
PEERJ, 2013, 1
[5]   Single-trial analysis and classification of ERP components - A tutorial [J].
Blankertz, Benjamin ;
Lemm, Steven ;
Treder, Matthias ;
Haufe, Stefan ;
Mueller, Klaus-Robert .
NEUROIMAGE, 2011, 56 (02) :814-825
[6]   Usability of four commercially-oriented EEG systems [J].
Hairston, W. David ;
Whitaker, Keith W. ;
Ries, Anthony J. ;
Vettel, Jean M. ;
Bradford, J. Cortney ;
Kerick, Scott E. ;
McDowell, Kaleb .
JOURNAL OF NEURAL ENGINEERING, 2014, 11 (04)
[7]  
Jun Lv, 2008, 2008 3rd International Conference on Innovative Computing Information and Control (ICICIC), DOI 10.1109/ICICIC.2008.196
[8]   Multi-channel EEG recordings during 3,936 grasp and lift trials with varying weight and friction [J].
Luciw, Matthew D. ;
Jarocka, Ewa ;
Edin, Benoni B. .
SCIENTIFIC DATA, 2014, 1
[9]   Are low cost Brain Computer Interface headsets ready for motor imagery applications? [J].
Martinez-Leon, Juan-Antonio ;
Cano-Izquierdo, Jose-Manuel ;
Ibarrola, Julio .
EXPERT SYSTEMS WITH APPLICATIONS, 2016, 49 :136-144
[10]  
McConnell A. C, 2017, Front. Mech. Eng, V3, P3, DOI [DOI 10.3389/FMECH.2017.00003, 10.3389/fmech.2017.00003]