Water management in a single cell proton exchange membrane fuel cells with a serpentine flow field

被引:33
|
作者
Hassan, Nik Suhaimi Mat [1 ]
Daud, Wan Ramli Wan [1 ]
Sopian, Kamaruzzaman [1 ]
Sahari, Jaafar [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fuel Cell Inst, Bangi 43600, Selangor, Malaysia
关键词
Water management; PEMFC; Moisture profile; Mass transfer coefficient; Diffusivity; THE-CHANNEL MODEL; 2-PHASE FLOW; EXTERNAL HUMIDIFICATION; MATHEMATICAL-MODEL; TRANSPORT; PEMFC; AIR; TEMPERATURE; TRANSIENT; SIMULATIONS;
D O I
10.1016/j.jpowsour.2009.01.066
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Gas and water management is the key to achieving good performance from a polymer electrolyte membrane fuel cell (PEMFC) stack. Imbalance between production and evaporation rates can result in either flooding of the electrodes or membrane dehydration, both of which severely limit fuel cell performance. In the present study, a mathematical model was developed to evaluate moisture profiles of hydrogen and air flows in the flow field channels of both the anode and the cathode. For model validation, a single fuel cell was designed with an active area of 200 cm(2). Six humidity sensors were installed in the flow fields of both the anode and the cathode at 457 mm, 1266 mm and 2532 mm from the inlets. The experiment was performed using an Arbin Fuel Cell Test Station. The temperature was varied (25 degrees C, 40 degrees C, 50 degrees C and 60 degrees C), while hydrogen and air velocities were fixed at 3 L min(-1) and 6 L min(-1), respectively, during the operation of the single cell. The feed relative humidity at the anode was fixed at 1.0, while the feed relative humidity at the cathode was fixed at 0.005 (dry air). All humidity sensor readings were taken at steady state after 2 h of operation. Model predictions were then compared with experimental results by using the least squares algorithm. The moisture content was found to decrease along the flow field at the anode, but to increase at the cathode. The moisture content profile at the anode was shown to depend on the moisture Peclet number, which decreased with temperature. On the other hand, the moisture profile at the cathode was shown to depend on both the Peclet number and the Damkohler number. The trend of the Peclet number in the cathode followed closely that of the anode. The Damkohler number decreased with temperature, indicating increasing moisture mass transfer with temperature. The moisture profile models were successfully validated by the published data of the estimated overall mass transfer coefficient and moisture effective diffusivity of the same order of magnitude. The strategy of saturating the hydrogen feed and using dry air, as in the present work, has been shown to Successfully prevent water droplet formation in the cathode, and hence prevent flooding. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [31] Numerical study of porous flow field designs for proton exchange membrane fuel cells
    Zhang, Yinghui
    Shao, Jing
    Tao, Youkun
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (02) : 1894 - 1908
  • [32] Evaluation of flow field design effects on proton exchange membrane fuel cell performance
    Weng, Fang-Bor
    Dlamini, Mangaliso Menzi
    Hwang, Jenn-Jiang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (39) : 14866 - 14884
  • [33] Experimental research on water management in proton exchange membrane fuel cells
    Yu, Li-jun
    Chen, Wen-can
    Qin, Ming-jun
    Ren, Geng-po
    JOURNAL OF POWER SOURCES, 2009, 189 (02) : 882 - 887
  • [34] Comparative computational fluid dynamic analysis between split and dual serpentine flow field for proton exchange membrane fuel cells
    Gundalabhagavan Amarnath
    A. Veeresh Babu
    Chemical Papers, 2023, 77 : 5033 - 5045
  • [35] The effects of flow-field orientation on water management in PEM fuel cells with serpentine channels
    Ashrafi, Moosa
    Shams, Mehrzad
    APPLIED ENERGY, 2017, 208 : 1083 - 1096
  • [36] Review on water management methods for proton exchange membrane fuel cells
    Wang, X. R.
    Ma, Y.
    Gao, J.
    Li, T.
    Jiang, G. Z.
    Sun, Z. Y.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (22) : 12206 - 12229
  • [37] Optimization of active area of proton exchange membrane fuel cell with better water management
    Karthikeyan, M.
    Muthukumar, M.
    Karthikeyan, P.
    Mathan, C.
    JOURNAL OF CERAMIC PROCESSING RESEARCH, 2019, 20 (05): : 490 - 498
  • [38] Numerical simulation and visualization study of a new tapered-slope serpentine flow field in proton exchange membrane fuel cell
    Huang, Haozhong
    Liu, Mingxin
    Li, Xuan
    Guo, Xiaoyu
    Wang, Tongying
    Li, Songwei
    Lei, Han
    ENERGY, 2022, 246
  • [39] Flow and mass transfer characteristics of the novel hierarchical flow field in proton exchange membrane fuel cells
    Sun, Lu-Yi
    Lin, Lin
    Zheng, Shao-Fei
    Bai, Ming-Jie
    Gao, Bo
    Wang, Xiao-Dong
    APPLIED THERMAL ENGINEERING, 2025, 273
  • [40] Numerical Analysis of Different Multi-serpentine Flow Fields for Proton Exchange Membrane Fuel Cells
    Liu, H. C.
    Yang, W. M.
    Cheng, L. S.
    Tan, J.