The quality of intrapartum fetal heart rate monitoring

被引:49
作者
Bakker, PCAM [1 ]
Colenbrander, GJ [1 ]
Verstraeten, AA [1 ]
Van Geijn, HP [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Med, Dept Obstet & Gynecol, NL-1007 MB Amsterdam, Netherlands
关键词
fetal heart rate; cardiotocographs; signal loss;
D O I
10.1016/j.ejogrb.2004.01.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the quality of fetal heart rate (FHR) recordings during the first and second stage of labor by quantifying the amount of fetal signal loss in relation to the method of monitoring: external ultrasound or directly via a scalp electrode. Study Design: Analysis of 239 intrapartum recordings stored between I January 2001 and I July 2001 from consecutive deliveries at the Vrije Universiteit Medical Center in Amsterdam. Singletons delivered via the vaginal route were included in the study. FHR recordings had duration of at least I It prior to birth of the infant. Subdivision in three groups took place on the basis of the recording technique which had been used; i.e. ultrasound, scalp electrode or a combination of both methods. FHR data was obtained using HP-M1350 cardiotocographs. The status (pen on, pen off, maternal signal) and the mode of the signals were acquired. The duration of pen lifts and maternal signals was divided by the total duration of the recording. Statistical analyses were performed with the Mann-Whitney U-test and the Wilcoxon signed ranks test. Results: Recordings obtained via ultrasound demonstrated significantly more fetal signal loss than those obtained via the direct mode, particularly in the second stage. The FIGO criteria for fetal signal loss with external ultrasound were not fulfilled during this stage for about half the cases. Conclusion: Intrapartum FHR monitoring via a scalp electrode provides far better quality FHR signals than external ultrasound and deserves a more prominent position in fetal surveillance than it currently has. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 17 条
  • [1] Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring:: a Swedish randomised controlled trial
    Amer-Wählin, I
    Hellsten, C
    Norén, H
    Hagberg, H
    Herbst, A
    Kjellmer, I
    Lilja, H
    Lindoff, C
    Månsson, M
    Mårtensson, L
    Olofsson, P
    Sundström, AK
    Marsál, K
    [J]. LANCET, 2001, 358 (9281) : 534 - 538
  • [2] [Anonymous], 1987, Int J Gynecol Obstet
  • [3] *CLIN EFF SUPP UN, 2001, US EL FET MON US CAR
  • [4] NUMERICAL-ANALYSIS OF THE HUMAN-FETAL HEART-RATE - THE QUALITY OF ULTRASOUND RECORDS
    DAWES, GS
    VISSER, GHA
    GOODMAN, JDS
    REDMAN, CWG
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 141 (01) : 43 - 52
  • [5] FREEMAN RK, 1981, FETAL MONITORING, P28
  • [6] GIBB D, 1992, FETAL MONITORING PRA, P1
  • [7] Ingemarsson I, 1993, FETAL HEART RATE MON, P12
  • [8] Kripke CC, 1999, AM FAM PHYSICIAN, V59, P2416
  • [9] NEILSON JP, 2003, FETAL ELECTROCARDIOG
  • [10] Fetal heart rate monitoring: Is it salvageable?
    Parer, JT
    King, T
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 182 (04) : 982 - 987