Prototype energy models for data centers

被引:34
|
作者
Sun, Kaiyu [1 ]
Luo, Na [1 ]
Luo, Xuan [1 ]
Hong, Tianzhen [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Bldg Technol & Urban Syst Div, One Cyclotron Rd, Berkeley, CA 94720 USA
关键词
Data center; EnergyPlus; Energy efficiency; Prototype energy model; Approach temperature; OpenStudio; AIR-DISTRIBUTION SYSTEMS; BUILDING ENERGY; PERFORMANCE; SIMULATION; DENSITY; FLOW; MANAGEMENT;
D O I
10.1016/j.enbuild.2020.110603
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Data centers in the United States consume about two percent of the nation's electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy's Commercial Prototype Building Models. This study presented the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft(2) (430 and 1076 W/m(2)) for the computer room, and 100 and 500 W/ft(2) (1076 and 5382 W/m(2)) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Energy Aware Virtual Machine Scheduling in Data Centers
    Qiu, Yeliang
    Jiang, Congfeng
    Wang, Yumei
    Ou, Dongyang
    Li, Youhuizi
    Wan, Jian
    ENERGIES, 2019, 12 (04)
  • [2] Machine learning assisted development of IT equipment compact models for data centers energy planning
    Manaserh, Yaman M.
    Tradat, Mohammad I.
    Bani-Hani, Dana
    Alfallah, Aseel
    Sammakia, Bahgat G.
    Nemati, Kourosh
    Seymour, Mark J.
    APPLIED ENERGY, 2022, 305
  • [3] A review of energy efficiency evaluation metrics for data centers
    Shao, Xiaotong
    Zhang, Zhongbin
    Song, Ping
    Feng, Yanzhen
    Wang, Xiaolin
    ENERGY AND BUILDINGS, 2022, 271
  • [4] A review of air conditioning energy performance in data centers
    Ni, Jiacheng
    Bai, Xuelian
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 625 - 640
  • [5] Balanced comparative assessment of thermal performance and energy efficiency for three cooling solutions in data centers
    Cho, Jinkyun
    Lim, Seung-beom
    ENERGY, 2023, 285
  • [6] A survey of energy-saving technologies in cloud data centers
    Cheng, Huiwen
    Liu, Bo
    Lin, Weiwei
    Ma, Zehua
    Li, Keqin
    Hsu, Ching-Hsien
    JOURNAL OF SUPERCOMPUTING, 2021, 77 (11) : 13385 - 13420
  • [7] Optimizing energy consumption for data centers
    Rong, Huigui
    Zhang, Haomin
    Xiao, Sheng
    Li, Canbing
    Hu, Chunhua
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 58 : 674 - 691
  • [8] A review of energy efficiency evaluation technologies in cloud data centers
    Long, Saiqin
    Li, Yuan
    Huang, Jinna
    Li, Zhetao
    Li, Yanchun
    ENERGY AND BUILDINGS, 2022, 260
  • [9] Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers
    Su, Lin
    Huang, Zhilin
    Dong, Kaijun
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (04)
  • [10] Free cooling technologies for data centers: energy saving mechanism and applications
    Zhang, Yin
    Wei, Zhiyuan
    Zhang, Mingshan
    LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 410 - 415