muscle synergy; EMG-driven modeling; stroke; principal component analysis (PCA); non-negative matrix factorization (NMF); muscle excitation; EMG normalization; JOINT MOMENTS; MATRIX FACTORIZATION; DYNAMIC SIMULATIONS; NEURAL-CONTROL; LOWER-LIMB; FORCE; WALKING; MODEL; OPTIMIZATION; PATTERNS;
D O I
10.3389/fncom.2020.588943
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electromyography (EMG)-driven musculoskeletal modeling relies on high-quality measurements of muscle electrical activity to estimate muscle forces. However, a critical challenge for practical deployment of this approach is missing EMG data from muscles that contribute substantially to joint moments. This situation may arise due to either the inability to measure deep muscles with surface electrodes or the lack of a sufficient number of EMG channels. Muscle synergy analysis (MSA) is a dimensionality reduction approach that decomposes a large number of muscle excitations into a small number of time-varying synergy excitations along with time-invariant synergy weights that define the contribution of each synergy excitation to all muscle excitations. This study evaluates how well missing muscle excitations can be predicted using synergy excitations extracted from muscles with available EMG data (henceforth called "synergy extrapolation" or SynX). The method was evaluated using a gait data set collected from a stroke survivor walking on an instrumented treadmill at self-selected and fastest-comfortable speeds. The evaluation process started with full calibration of a lower-body EMG-driven model using 16 measured EMG channels (collected using surface and fine wire electrodes) per leg. One fine wire EMG channel (either iliopsoas or adductor longus) was then treated as unmeasured. The synergy weights associated with the unmeasured muscle excitation were predicted by solving a nonlinear optimization problem where the errors between inverse dynamics and EMG-driven joint moments were minimized. The prediction process was performed for different synergy analysis algorithms (principal component analysis and non-negative matrix factorization), EMG normalization methods, and numbers of synergies. SynX performance was most influenced by the choice of synergy analysis algorithm and number of synergies. Principal component analysis with five or six synergies consistently predicted unmeasured muscle excitations the most accurately and with the greatest robustness to EMG normalization method. Furthermore, the associated joint moment matching accuracy was comparable to that produced by initial EMG-driven model calibration using all 16 EMG channels per leg. SynX may facilitate the assessment of human neuromuscular control and biomechanics when important EMG signals are missing.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Age-related differences in gait symmetry obtained from kinematic synergies and muscle synergies of lower limbs during childhood
    Xiong, Qiliang
    Wan, Jinliang
    Jiang, Shaofeng
    Liu, Yuan
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [32] Inhibitory Components in Muscle Synergies Factorized by the Rectified Latent Variable Model From Electromyographic Data
    Guo, Xiaoyu
    Huang, Subing
    He, Borong
    Lan, Chuanlin
    Xie, Jodie J.
    Lau, Kelvin Y. S.
    Takei, Tomohiko
    Mak, Arthur D. P.
    Cheung, Roy T. H.
    Seki, Kazuhiko
    Cheung, Vincent C. K.
    Chan, Rosa H. M.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (02) : 1049 - 1061
  • [33] A Muscle Synergy-Inspired Control Design to Coordinate Functional Electrical Stimulation and a Powered Exoskeleton ARTIFICIAL GENERATION OF SYNERGIES TO REDUCE INPUT DIMENSIONALITY
    Alibeji, Naji A.
    Molazadeh, Vahidreza
    Moore-Clingenpeel, Frank
    Sharma, Nitin
    IEEE CONTROL SYSTEMS MAGAZINE, 2018, 38 (06): : 35 - 60
  • [34] Prediction of Actively Exerted Torque From Ankle Joint Complex Based on Muscle Synergy
    Zhou, Yu
    Li, Jianfeng
    Dong, Mingjie
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (02) : 1729 - 1737
  • [35] Muscle Synergy Constraints Do Not Improve Estimates of Muscle Activity From Static Optimization During Gait for Unimpaired Children or Children With Cerebral Palsy
    Shuman, Benjamin R.
    Goudriaan, Marije
    Desloovere, Kaat
    Schwartz, Michael H.
    Steele, Katherine M.
    FRONTIERS IN NEUROROBOTICS, 2019, 13
  • [36] Factorization of EMG via muscle synergies in walking task: evaluation of intra-subject and inter-subject variability
    Taborri, Juri
    Palermo, Eduardo
    Masiello, Denisa
    Rossi, Stefano
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 708 - 713
  • [37] Hybrid neuromusculoskeletal modeling to best track joint moments using a balance between muscle excitations derived from electromyograms and optimization
    Sartori, Massimo
    Farina, Dario
    Lloyd, David G.
    JOURNAL OF BIOMECHANICS, 2014, 47 (15) : 3613 - 3621
  • [38] Extracting Muscle Synergy Patterns from EMG Data Using Autoencoders
    Spueler, Martin
    Irastorza-Landa, Nerea
    Sarasola-Sanz, Andrea
    Ramos-Murguialday, Ander
    ARTIFICIAL NEURAL NETWORKS AND MACHINE LEARNING - ICANN 2016, PT II, 2016, 9887 : 47 - 54
  • [39] Evaluation of Muscle Synergies Stability in Human Locomotion: A comparison between normal and fast walking speed
    Rimini, D.
    Agostini, V.
    Knaflitz, M.
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 404 - 408
  • [40] Predicting the metabolic cost of incline walking from muscle activity and walking mechanics
    Slider, Amy
    Besier, Thor
    Delp, Scott L.
    JOURNAL OF BIOMECHANICS, 2012, 45 (10) : 1842 - 1849