Multigap Resistive Plate Chambers for Time of Flight Applications

被引:8
|
作者
Wang, Yi [1 ]
Yu, Yancheng [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
基金
中国国家自然科学基金;
关键词
multigap resistive plate chamber; time of flight; high energy physics experiments; particle identification; time resolution; SILICON PHOTOMULTIPLIER; READOUT ELECTRONICS; STAR EXPERIMENT; RATE CAPABILITY; ULTRA-FAST; DETECTOR; GAS; SIMULATION; RESOLUTION; TOF;
D O I
10.3390/app11010111
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
With the advantages of high-performance, easy to build and relatively low cost, the multigap resistive plate chamber has been arousing broad interests over the last few decades. It has become a new standard technology for the time of flight system in high energy physics experiments. In this article, we will give a description of the structure and the operating principles of the MRPC detector and focus on reviewing the applications on the time of flight system in several famous experiments. The performances, including time resolution and particle identification, are discussed in detail. Some recent advances and points of view for the future development of the next generation MRPC are also outlined.
引用
收藏
页码:1 / 23
页数:23
相关论文
共 50 条
  • [41] Construction and performance of a prototype multigap resistive plate chamber
    Ahn, SH
    Hong, B
    Hong, SJ
    Ji, JR
    Lee, KS
    Lee, SB
    Park, S
    Park, WJ
    Ryu, MS
    Shim, HH
    Sim, KS
    Woo, JK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2002, 40 (02) : 366 - 368
  • [42] A new type of resistive plate chamber: The multigap RPC
    Zeballos, EC
    Crotty, I
    Hatzifotiadou, D
    Valverde, JL
    Neupane, S
    Williams, MCS
    Zichichi, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (01): : 132 - 135
  • [43] Latest results from the multigap resistive plate chamber
    Zeballos, EC
    Crotty, I
    Hatzifotiadou, D
    Valverde, JL
    Williams, MCS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 145 - 149
  • [44] Time response functions and avalanche fluctuations in resistive plate chambers
    Riegler, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02): : 377 - 390
  • [45] Operation of a multigap resistive plate chamber in the streamer mode
    Ryu, MS
    Hong, B
    Lee, KS
    Park, S
    Sim, KS
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (05) : 905 - 908
  • [46] Performance of multigap resistive plate chamber in a γ-ray aging test
    WU Yue-Lei WANG Xiao-Lian ZOU Tao ZHAO Yan-E DONG Xin XU Zi-Zong (Department of Modern Physics
    NuclearScienceandTechniques, 2006, (05) : 293 - 296
  • [47] Improvement of time measurement with the INO-ICAL resistive plate chambers
    Bhatt, A. D.
    Datar, V. M.
    Majumder, G.
    Mondal, N. K.
    Pathaleswar
    Satyanarayana, B.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [48] Resistive plate chambers for tomography and radiography
    Thomay, C.
    Baesso, P.
    Cussans, D.
    Davies, J.
    Glaysher, P.
    Quillin, S.
    Robertson, S.
    Steer, C.
    Vassallo, C.
    Velthuis, J.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2012, 1 (02) : 235 - 238
  • [49] Simulation of the CMS Resistive Plate Chambers
    Hadjiiska, R.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Dimitrov, A.
    Beernaert, K.
    Cimmino, A.
    Costantini, S.
    Garcia, G.
    Lellouch, J.
    Marinov, A.
    Ocampo, A.
    Strobbe, N.
    Thyssen, F.
    Tytgat, M.
    Verwilligen, P.
    Yazgan, E.
    Zaganidis, N.
    Aleksandrov, A.
    Genchev, V.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Ban, Y.
    Cai, J.
    Xue, Z.
    Ge, Y.
    Li, Q.
    Qian, S.
    Avila, C.
    Chaparro, L. F.
    Gomez, J. P.
    Gomez Moreno, B.
    Osorio Oliveros, A. F.
    Sanabria, J. C.
    Assran, Y.
    Sharma, A.
    Abbrescia, M.
    Colaleo, A.
    Pugliese, G.
    Loddo, F.
    Calabria, C.
    Maggi, M.
    Benussi, L.
    Bianco, S.
    Colafranceschi, S.
    Piccolo, D.
    Carrillo, C.
    Iorio, O.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [50] Time resolution of resistive plate chambers investigated with 10 MeV electrons
    Paradela, C.
    Ayyad, Y.
    Benlliure, J.
    Casarejos, E.
    Duran, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 94 - 101