Optimization of UV-Electroproxone procedure for treatment of landfill leachate: the study of energy consumption

被引:16
|
作者
Kermani, Majid [1 ,2 ]
Shahsavani, Abbas [3 ,4 ]
Ghaderi, Pegah [5 ]
Kasaee, Pooria [6 ]
Mehralipour, Jamal [7 ,8 ]
机构
[1] Iran Univ Med Sci, Res Ctr Environm Hlth Technol, Tehran, Iran
[2] Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Environm & Occupat Hazards Control Res Ctr, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[5] Islamic Azad Univ, West Tehran Branch, Environm Engn Water & Wastewater, Tehran, Iran
[6] Azad Univ, Tehran West Branch, Civil Engn, Tehran, Iran
[7] Iran Univ Med Sci, Student Res Comm, Tehran, Iran
[8] Iran Univ Med Sci, Environm Hlth Engn, Tehran, Iran
关键词
Optimization; UV-Electroproxone process; landfill leachate; Design Expert software;
D O I
10.1007/s40201-020-00583-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With increased population, treatment of solid waste landfill and its leachate is of major concern. Municipal landfill leachate shows variable, heterogeneous and incontrollable characteristics and contains wide range highly concentrated organic and inorganic compounds, in which hampers the application of a solo method in its treatment. Among different approaches, biological treatment can be used, however it is not effective enough to elimination all refractory organics, containing fulvic-like and humic-like substance. In this experimental study, the UV Electroperoxone process as a hybrid procedure has been employed to treat landfill leachate. The effect of various parameters such as pH, electrical current density, ozone concentration, and reaction time were optimized using central composite design (CCD). In the model fitting, the quadratic model with a P-Value less than 0.5 was suggested (< 0.0001). The R-2, R-2 adj, and R-2 pre were determined equal to 0.98,0.96, and 0.91 respectively. Based on the software prediction, the process can remove 83% of initial COD, in the optimum condition of pH = 5.6, ozone concentration of 29.1 mg/l. min, the current density of 74.7 mA/cm(2), and process time of 98.6 min. In the optimum condition, 55/33 mM H2O2 was generated through electrochemical mechanism. A combination of ozonation, photolysis and electrolysis mechanism in this hybrid process increases COD efficiency removal up 29 percent which is higher than the sum of separated mechanisms. Kinetic study also demonstrated that the UV-EPP process follows pseudo-first order kinetics (R-2 = 0.99). Based on our results, the UV-EPP process can be informed as an operative technique for treatment of old landfills leachates.
引用
收藏
页码:81 / 93
页数:13
相关论文
共 50 条
  • [1] Optimization of UV-Electroproxone procedure for treatment of landfill leachate: the study of energy consumption
    Majid Kermani
    Abbas Shahsavani
    Pegah Ghaderi
    Pooria Kasaee
    Jamal Mehralipour
    Journal of Environmental Health Science and Engineering, 2021, 19 : 81 - 93
  • [2] Energy consumption by forward osmosis treatment of landfill leachate for water recovery
    Iskander, Syeed Md
    Zou, Shiqiang
    Brazil, Brian
    Novak, John T.
    He, Zhen
    WASTE MANAGEMENT, 2017, 63 : 284 - 291
  • [3] Optimization of Fenton process for the treatment of landfill leachate
    Zhang, H
    Choi, HJ
    Huang, CP
    JOURNAL OF HAZARDOUS MATERIALS, 2005, 125 (1-3) : 166 - 174
  • [4] Optimization of the landfill leachate treatment by the Fenton process
    Vilar, Almudena
    Eiroa, Marta
    Kennes, Christian
    Veiga, Maria C.
    WATER AND ENVIRONMENT JOURNAL, 2013, 27 (01) : 120 - 126
  • [5] Landfill leachate treatment with electrocoagulation: optimization by using Taguchi method
    Apaydin, Omer
    Ozkan, Ebru
    DESALINATION AND WATER TREATMENT, 2020, 173 : 65 - 76
  • [6] Optimization of Process Conditions on Landfill Leachate Treatment by CWAO Method
    Zhang, Yongli
    Sun, Yanling
    MATERIALS ENGINEERING AND TECHNOLOGY, 2014, 849 : 137 - 141
  • [7] Optimization of Fresh Landfill Leachate Treatment by a Response Surface Methodology
    Bakraouy, H.
    Abouri, M.
    Souabi, S.
    Digua, K.
    Yaacoubi, A.
    Jada, A.
    JOURNAL OF COLLOID SCIENCE AND BIOTECHNOLOGY, 2016, 5 (02) : 182 - 189
  • [8] Doehlert experimental design for the optimization of electrocoagulation treatment of landfill leachate
    Mansour, Dorsaf
    El-Sofany, Walaa, I
    Abdella, Faiza I. A.
    Masood, Najat
    Alsukaibi, Abdulmohsen Khalaf Dhahi
    Bellakhal, Nizar
    ENVIRONMENTAL POLLUTANTS AND BIOAVAILABILITY, 2021, 33 (01) : 395 - 401
  • [9] Optimization and kinetic analysis of electrocoagulation-assisted adsorption for treatment of young landfill leachate
    Kundu, Ashmita
    Gupta, Navinkumar
    Kalamdhad, Ajay S.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 366
  • [10] Study on the Treatment Effect of Ammonia in Landfill Leachate by Recirculation
    Liu, Shan
    Zhang, Zhen Bo
    Li, Yue
    Gao, Wen Yi
    FUTURE MATERIALS ENGINEERING AND INDUSTRY APPLICATION, 2012, 365 : 396 - +