Ultrasensitive Cross-species Measurement of Cardiac Troponin-I Using the Erenna Immunoassay System

被引:28
|
作者
Schultze, A. Eric [1 ]
Konrad, Robert J. [2 ]
Credille, Kelly M. [1 ]
Lu, Quynh Anh [3 ]
Todd, John [3 ]
机构
[1] Lilly Res Labs, Dept Pathol, Greenfield, IN 46140 USA
[2] Lilly Res Labs, Expt Med Lab, Greenfield, IN 46140 USA
[3] Singulex Inc, Alameda, CA USA
关键词
cardiac troponin; cardiotoxicity; cTnI; rat; human; dog; monkey;
D O I
10.1177/0192623308322016
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Serum cardiac troponin-I (cTnI) has been validated as a biomarker for cardiotoxicity in numerous animal models; however, owing to sensitivity issues cTnI concentrations in healthy, resting animals used in toxicology studies have not been established. Serum from healthy and isoproterenol hydrochloride (iso)-treated rats, dogs, and monkeys were assayed using the Erenna system. The Erenna cTnI assay provided sensitivity < 1 ng/L across human, rat, dog, and monkey cTnI. Linear responses (R-2 = 0.99) were observed for all species. Precision studies yielded interassay CVs of curve fit quantification from 2% to 4% between 1.6 and 5000 ng/L, and 23% at 0.78 ng/L. Strong correlation (R2 = 0.99) was obtained between Erenna and Beckman Access cTnI. Concentrations of cTnI in healthy animals ranged from 1 to 9 ng/L. In longitudinal studies of iso-treated animals, the concentrations of cTnI in the control vehicle-treated groups were 10-20 ng/L for rats (N = 10) and predose values of 2-3 ng/L for dogs (N = 3). Measured with the Erenna assay system, cTnI was quantifiable at all time intervals tested in all animals treated with iso. The Erenna system provides sensitive measurement of cTnI in rats, dogs, and monkeys, makes it possible to determine small changes from normal concentrations, and provides cTnI values from small volumes of serum.
引用
收藏
页码:777 / 782
页数:6
相关论文
共 50 条
  • [21] Differential reactivity of cardiac and skeletal muscle from various species in a cardiac troponin I immunoassay
    O'Brien, PJ
    Landt, Y
    Ladenson, JH
    CLINICAL CHEMISTRY, 1997, 43 (12) : 2333 - 2338
  • [22] Fully Automated Ultrasensitive Digital Immunoassay for Cardiac Troponin I Based on Single Molecule Array Technology
    Jarolim, Petr
    Patel, Purvish P.
    Conrad, Michael J.
    Chang, Lei
    Melenovsky, Vojtech
    Wilson, David H.
    CLINICAL CHEMISTRY, 2015, 61 (10) : 1283 - 1291
  • [23] Ultrasensitive magnetic field-assisted surface plasmon resonance immunoassay for human cardiac troponin I
    Wu, Qiong
    Sun, Ying
    Zhang, Di
    Li, Shuo
    Zhang, Yue
    Ma, Pinyi
    Yu, Yang
    Wang, Xinghua
    Song, Daqian
    BIOSENSORS & BIOELECTRONICS, 2017, 96 : 288 - 293
  • [24] Ratiometric fluorescent immunoassay for the cardiac troponin-I using carbon dots and palladium-iridium nanocubes with peroxidase-mimicking activity
    Tan, Xiaofeng
    Zhang, Lianhua
    Tang, Qiaorong
    Zheng, Gengxiu
    Li, He
    MICROCHIMICA ACTA, 2019, 186 (05)
  • [25] Ratiometric fluorescent immunoassay for the cardiac troponin-I using carbon dots and palladium-iridium nanocubes with peroxidase-mimicking activity
    Xiaofeng Tan
    Lianhua Zhang
    Qiaorong Tang
    Gengxiu Zheng
    He Li
    Microchimica Acta, 2019, 186
  • [26] Development of a troponin-I assay for diagnosis of acute myocardial infarction on an automated chemiluminescence immunoassay system.
    Orswell, M
    Tasaico, K
    Oh, SK
    Bluestein, B
    CLINICAL CHEMISTRY, 1997, 43 : 37 - 37
  • [27] Clinical evaluation of cardiac troponin I (cTnI) measurement using the Stratus CS and Immulite immunoassay systems.
    Gaze, DC
    Collinson, PO
    CLINICAL CHEMISTRY, 2001, 47 (06) : A201 - A201
  • [28] HIGHLY SPECIFIC IMMUNOASSAY FOR CARDIAC TROPONIN-I ASSESSED IN NONINFARCT PATIENTS WITH CHRONIC-RENAL-FAILURE OR SEVERE POLYTRAUMA
    TRINQUIER, S
    FLECHEUX, O
    BULLENGER, M
    CASTEX, F
    CLINICAL CHEMISTRY, 1995, 41 (11) : 1675 - 1676
  • [29] Ultrasensitive Upconversion Nanoparticle Immunoassay for Human Serum Cardiac Troponin I Detection Achieved with Resonant Waveguide Grating
    Tseng, Yen-Ta
    Chiu, Yu-Chung
    Pham, Van-Dai
    Wu, Wen-Hsuan
    Le-Vu, Thanh Thu
    Wang, Chih-Hsien
    Kuo, Shiao-Wei
    Chan, Michael W. Y.
    Lin, Chun-Hung
    Li, Szu-Chin
    Li, Yi-Da
    Kan, Hung-Chih
    Lin, Jiunn-Yuan
    Chau, Lai-Kwan
    Hsu, Chia-Chen
    ACS SENSORS, 2024, 9 (01) : 455 - 463
  • [30] USE OF ENZYME-IMMUNOASSAY FOR MEASUREMENT OF SKELETAL TROPONIN-I UTILIZING ISOFORM-SPECIFIC MONOCLONAL-ANTIBODIES
    TAKAHASHI, M
    LEE, L
    SHI, QW
    GAWAD, Y
    JACKOWSKI, G
    CLINICAL CHEMISTRY, 1995, 41 (06) : S61 - S61