Bundle branch reentrant tachycardia in a patient with normal ventricular function

被引:5
作者
Fynn, SP
Kalman, JM
机构
[1] Royal Melbourne Hosp, Dept Cardiol, Parkville, Vic 3050, Australia
[2] Univ Melbourne, Dept Med, Parkville, Vic 3050, Australia
关键词
bundle branch reentrant tachycardia; implantable defibrillator;
D O I
10.1023/B:JICE.0000026921.40512.21
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report an unusual case of bundle branch reentrant tachycardia, in a patient with normal left ventricular function, cured by radiofrequency catheter ablation. However, the long-term prognosis of these patients is uncertain. We discuss the indications for an implantable defibrillator in this group.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 14 条
[1]   BUNDLE-BRANCH REENTRY - A MECHANISM OF VENTRICULAR-TACHYCARDIA IN THE ABSENCE OF MYOCARDIAL OR VALVULAR DYSFUNCTION [J].
BLANCK, Z ;
JAZAYERI, M ;
DHALA, A ;
DESHPANDE, S ;
SRA, J ;
AKHTAR, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (06) :1718-1722
[2]   BUNDLE-BRANCH REENTRANT VENTRICULAR-TACHYCARDIA - CUMULATIVE EXPERIENCE IN 48 PATIENTS [J].
BLANCK, Z ;
DHALA, A ;
DESHPANDE, S ;
SRA, J ;
JAZAYERI, M ;
AKHTAR, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1993, 4 (03) :253-262
[3]   SUSTAINED BUNDLE-BRANCH REENTRY AS A MECHANISM OF CLINICAL TACHYCARDIA [J].
CACERES, J ;
JAZAYERI, M ;
MCKINNIE, J ;
AVITALL, B ;
DENKER, ST ;
TCHOU, P ;
AKHTAR, M .
CIRCULATION, 1989, 79 (02) :256-270
[4]   RADIOFREQUENCY CATHETER ABLATION FOR TREATMENT OF BUNDLE-BRANCH REENTRANT VENTRICULAR-TACHYCARDIA - RESULTS AND LONG-TERM FOLLOW-UP [J].
COHEN, TJ ;
CHIEN, WW ;
LURIE, KG ;
YOUNG, C ;
GOLDBERG, HR ;
WANG, YS ;
LANGBERG, JJ ;
LESH, MD ;
LEE, MA ;
GRIFFIN, JC ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) :1767-1773
[5]  
Hachiya H, 2000, PACE, V23, P1930
[6]   Bundle branch reentrant tachycardia in patients with apparent normal His-Purkinje conduction:: The role of functional conduction impairment [J].
Li, YG ;
Grönefeld, G ;
Israel, C ;
Bogun, F ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (12) :1233-1239
[7]   Long-term clinical outcome of right bundle branch radiofrequency catheter ablation for treatment of bundle branch reentrant ventricular tachycardia [J].
Mehdirad, AA ;
Kewi, S ;
Rist, K ;
Tchou, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (12) :2135-2143
[8]   RELATIONSHIP BETWEEN THE 12-LEAD ELECTROCARDIOGRAM DURING VENTRICULAR-TACHYCARDIA AND ENDOCARDIAL SITE OF ORIGIN IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MILLER, JM ;
MARCHLINSKI, FE ;
BUXTON, AE ;
JOSEPHSON, ME .
CIRCULATION, 1988, 77 (04) :759-766
[9]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[10]  
Narasimhan C, 1997, CIRCULATION, V96, P4307