Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques

被引:0
作者
Akiash, Nehzat [1 ]
Mombeini, Hoda [2 ,5 ]
Keshavarz, S. Zohreh [3 ]
Sheikhi, Mohammad Ali [4 ]
Gholizadeh, Behnam [4 ]
Kalantari, Ramtin Rezaee [4 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Imam Khomeini Hosp, Atherosclerosis Res Ctr, Ahvaz, Iran
[2] Univ Tehran Med Sci, Sina Hosp, Tehran, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Imam Khomeini Hosp, Gen Cardiol, Ahvaz, Iran
[4] Ahvaz Jundishapur Univ Med Sci, Atherosclerosis Res Ctr, Dept Cardiac Surg, Ahvaz, Iran
[5] Univ Tehran Med Sci, Sina Hosp, Atherosclerosis Res Ctr, Tehran, Iran
关键词
Echocardiography; Mitral Valve Annuloplasty; Mitral Valve; VALVE REPAIR; REGURGITATION; ANNULOPLASTY; INSIGHTS; DISEASE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Mitral Valve (MV) disease is responsible for a considerable number of open cardiac surgeries. Selecting a befitting prosthetic valve is a matter of consideration. Thus, accurate definition of mitral apparatus characteristics, particularly mitral annulus dimensions, preoperatively can shed some light on the situation. The less invasive nature of three-dimensional Transesophageal Echocardiography (3D-TEE) can turn it into a practical modality for preoperative investigation of mitral anatomy.Objectives: The present study aimed to investigate the correlation between the size of mitral annulus attained through 3D-TEE and intraoperative size as well as the valve or ring size finally placed in mitral position.Methods: The study was conducted on 28 patients suffering from MV disease who were candidates for MV surgery. All the patients underwent 3D-TEE. Mitral annulus diameters including anteroposterior and intercommissural diameters were measured delicately by using the Mitral Valve Navigation (MVN) tool. In the midst of surgery, a mitral ring sizer was utilized in order to suggest the proper prosthesis size.Results: The study results demonstrated that the sizer instrument was strongly associated with the inserted prosthesis size and moderately with echocardiographic annulus diameters. The correlation between the deployed prosthesis size and annulus size obtained by intraoperative sizer and 3D echocardiography was assessed, as well. The results indicated that ring sizer showed a strong positive relationship with the intercommissural echocardiography diameter and a moderate positive relationship with the anteroposterior echocardiography diameter.Conclusion: The results revealed a good correlation between the echocardiography measurements and intraoperative examination along with the deployed prosthesis size. Thus, 3D-TEE could be considered a practical modality for the preoperative investigation of mitral anatomy.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 25 条
  • [1] Secondary Mitral Regurgitation in Heart Failure Pathophysiology, Prognosis, and Therapeutic Considerations
    Asgar, Anita W.
    Mack, Michael J.
    Stone, Gregg W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (12) : 1231 - 1248
  • [2] A simplified D-shaped model of the mitral annulus to facilitate CT-based sizing before transcatheter mitral valve implantation
    Blanke, Philipp
    Dvir, Danny
    Cheung, Anson
    Ye, Jian
    Levine, Robert A.
    Precious, Bruce
    Berger, Adam
    Stub, Dion
    Hague, Cameron
    Murphy, Darra
    Thompson, Christopher
    Munt, Brad
    Moss, Robert
    Boone, Robert
    Wood, David
    Pache, Gregor
    Webb, John
    Leipsic, Jonathon
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (06) : 459 - 467
  • [3] Sizing for Mitral Annuloplasty: Where Does Science Stop and Voodoo Begin?
    Bothe, Wolfgang
    Miller, D. Craig
    Doenst, Torsten
    [J]. ANNALS OF THORACIC SURGERY, 2013, 95 (04) : 1475 - 1483
  • [4] Results of mitral valve annuloplasty with a standard-sized posterior band: Is measuring important?
    Brown, Morgan L.
    Schaff, Hartzell V.
    Li, Zhuo
    Suri, Rakesh M.
    Daly, Richard C.
    Orszulak, Thomas A.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (04) : 886 - 891
  • [5] Quantitative Modeling of the Mitral Valve by Three-Dimensional Transesophageal Echocardiography in Patients Undergoing Mitral Valve Repair: Correlation with Intraoperative Surgical Technique
    Calleja, Anna
    Poulin, Frederic
    Woo, Anna
    Meineri, Massimiliano
    Jedrzkiewicz, Sean
    Vannan, Mani A.
    Rakowski, Harry
    David, Tirone
    Tsang, Wendy
    Thavendiranathan, Paaladinesh
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (09) : 1083 - 1092
  • [6] Castillo JG, 2011, REV ESP CARDIOL, V64, P1169, DOI [10.1016/j.recesp.2011.06.025, 10.1016/j.rec.2011.06.023]
  • [7] Mitral valve repair for degenerative mitral valve disease: surgical approach, patient selection and long-term outcomes
    Coutinho, Goncalo F.
    Antunes, Manuel J.
    [J]. HEART, 2017, 103 (21) : 1663 - 1669
  • [8] Mitral Valve Regurgitation in the Contemporary Era Insights Into Diagnosis, Management, and Future Directions
    El Sabbagh, Abdallah
    Reddy, Yogesh N. V.
    Nishimura, Rick A.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2018, 11 (04) : 628 - 643
  • [9] Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography
    Ender, J.
    Eibel, S.
    Mukherjee, C.
    Mathioudakis, D.
    Borger, M. A.
    Jacobs, S.
    Mohr, F. W.
    Falk, V.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (06): : 445 - 453
  • [10] Sizing the mitral annulus in healthy subjects and patients with mitral regurgitation: 2D versus 3D measurements from cardiac CT
    Gordic, Sonja
    Thi Dan Linh Nguyen-Kim
    Manka, Robert
    Suendermann, Simon
    Frauenfelder, Thomas
    Maisano, Francesco
    Falk, Volkmar
    Alkadhi, Hatem
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 389 - 398