Effect of optimal allocation of multiple DG and D-STATCOM in radial distribution system for minimising losses and THD

被引:0
作者
Gupta, Atma Ram [1 ]
机构
[1] NIT Kurukshetra, Elect Engn Dept, Kurukshetra 136119, Haryana, India
来源
2017 7TH INTERNATIONAL SYMPOSIUM ON EMBEDDED COMPUTING AND SYSTEM DESIGN (ISED) | 2017年
关键词
distributed generation; D-STATCOM; load flow; harmonic load flow; sensitivity analysis; radial distribution system; LOAD FLOW; PLACEMENT;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The expansion of power system has led to the increase of Distributed Generation (DG) to fulfil the increase in the load demand. The DG opted has led to the increase in the losses and voltage imbalance due to improper allocation. Rapid increase in nonlinear loads in our daily life has introduced the power quality problems in the power system in terms of harmonics. In this paper, the optimal placement of multiple DG and Distribution Static Compensator (D-STATCOM) in a radial distribution system is carried out which results in the reduction of line losses as well as Total Harmonic Distortion (THD). The optimal location of DG and D-STATCOM is determined by stability index. The optimal size of DG and D-STATCOM is determined using variation technique by increasing the size in steps. The load flow analysis and harmonic flow analysis is carried out on IEEE 34 bus system having the harmonic sources injected as current sources.
引用
收藏
页数:5
相关论文
共 15 条
  • [1] Test systems for harmonics modeling and simulation
    Abu-hashim, R
    Burch, R
    Chang, G
    Grady, M
    Gunther, E
    Halpin, M
    Hatziadoniu, C
    Liu, Y
    Marz, M
    Ortmeyer, T
    Rajagopalan, V
    Ranade, S
    Ribeiro, P
    Sims, T
    Xu, W
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) : 579 - 587
  • [2] Distributed generation:: a definition
    Ackermann, T
    Andersson, G
    Söder, L
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2001, 57 (03) : 195 - 204
  • [3] Amanifar O., 2011, 16 EL POW DISTR C, P1
  • [4] [Anonymous], ELECT POWER COMPONEN
  • [5] [Anonymous], 2015, AIN SHAMS ENG J
  • [6] Arunagiri A, 2011, J ENG SCI TECHNOL, V6, P300
  • [7] A voltage stability index for radial distribution networks
    Eminoglu, U.
    Hocaoglu, M. H.
    [J]. 2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 408 - 413
  • [8] Impact of DG and D-STATCOM placement on improving the reactive loading capability of mesh distribution system
    Gupta, Atma Ram
    Kumar, Ashwani
    [J]. 1ST GLOBAL COLLOQUIUM ON RECENT ADVANCEMENTS AND EFFECTUAL RESEARCHES IN ENGINEERING, SCIENCE AND TECHNOLOGY - RAEREST 2016, 2016, 25 : 676 - 683
  • [9] Energy savings using D-STATCOM placement in radial distribution system
    Gupta, Atma Ram
    Kumar, Ashwani
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON ECO-FRIENDLY COMPUTING AND COMMUNICATION SYSTEMS, 2015, 70 : 558 - 564
  • [10] Hussain S., 2012, IOSR J. Electr. Electron. Eng. (IOSRJEEE), V2, P17, DOI [10.9790/1676-0241723, DOI 10.9790/1676-0241723]