An Improved Phase-Shifted DPWM Method for Reducing Switching Loss and Thermal Balancing in Cascaded H-Bridge Multilevel Inverter

被引:19
作者
Kim, Seok-Min [1 ]
Lee, Eui-Jae [1 ]
Lee, June-Seok [2 ]
Lee, Kyo-Beum [1 ]
机构
[1] Ajou Univ, Dept Elect & Comp Engn, Suwon 16499, South Korea
[2] Dankook Univ, Sch Elect & Elect Engn, Yongin 16890, South Korea
来源
IEEE ACCESS | 2020年 / 8卷 / 08期
关键词
Switching loss; Pulse width modulation; Legged locomotion; Switches; Reliability; Discontinuous pulse-width modulation; power losses; power distribution; cascaded H-bridge multilevel inverter; reliability of power conversion system; RELIABILITY IMPROVEMENT; CONVERTER;
D O I
10.1109/ACCESS.2020.3030261
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes an improved discontinuous pulse-width modulation (DPWM) method based on phase-shifted PWM (PS-PWM) for three-phase cascaded H-bridge (CHB) multilevel inverters. Due to the CHB multilevel inverters employ a large number of power semiconductor switches, they suffer from device failures because the switches are one of the major failure factors in a power electronic system. Therefore, the reliability and life-time of CHB multilevel inverters are mainly determined by the reliability of switches. The most failure of switches is occurred by its accumulated thermal stress which is generated by power losses including the conduction and switching loss. By applying the conventional DPWM, the life-time of switches can be extended because it reduces the switching loss. The conventional DPWM, however, still operates with high speed carrier frequency and it is not enough to reduce the switching loss of the CHB multilevel inverter with a large number of inverter cells. The proposed novel DPWM method provides the improved switching loss reduction through the different switching behaviors for each leg. Additionally, the rotation scheme promises even power distribution and life-time management among inverter cells in a CHB multilevel inverter. The simulation results and experimental results confirm the switching loss reduction and even power distribution abilities of the proposed modulation method.
引用
收藏
页码:187072 / 187083
页数:12
相关论文
共 20 条
[1]   Hybrid Multilevel Converter With Cascaded H-bridge Cells for HVDC Applications: Operating Principle and Scalability [J].
Adam, G. P. ;
Abdelsalam, Ibrahim Abdallah ;
Ahmed, Khaled Hani ;
Williams, Barry W. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (01) :65-77
[2]   Reliability Improvement of Power Converters by Means of Condition Monitoring of IGBT Modules [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Jorgensen, Soren ;
Munk-Nielsen, Stig ;
Rannestad, Bjorn .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (10) :7990-7997
[3]   Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2517-2533
[4]   A Survey of Low Switching Frequency Modulation Techniques for Medium-Voltage Multilevel Converters [J].
Edpuganti, Amarendra ;
Rathore, Akshay Kumar .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (05) :4212-4228
[5]   A Modified Level-Shifted PWM Strategy for Fault-Tolerant Cascaded Multilevel Inverters With Improved Power Distribution [J].
Kim, Seok-Min ;
Lee, June-Seok ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (11) :7264-7274
[6]   Modified Phase-Shifted PWM Scheme for Reliability Improvement in Cascaded H-Bridge Multilevel Inverters [J].
Lee, Eui-Jae ;
Kim, Seok-Min ;
Lee, Kyo-Beum .
IEEE ACCESS, 2020, 8 (08) :78130-78139
[7]  
Lee JS, 2017, IEEE ENER CONV, P2100, DOI 10.1109/ECCE.2017.8096417
[8]  
Lee KB, 2017, POWER SYST, P1, DOI 10.1007/978-981-10-4992-7
[9]  
Lee K-B., 2019, Advanced Power Electronics
[10]   Thermal Loading and Lifetime Estimation for Power Device Considering Mission Profiles in Wind Power Converter [J].
Ma, Ke ;
Liserre, Marco ;
Blaabjerg, Frede ;
Kerekes, Tamas .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) :590-602