Behavior and Design Aspects of FRP-Strengthened URM Walls under Out-of-Plane Loading

被引:25
作者
Elsanadedy, H. M. [1 ]
Al-Salloum, Y. A. [2 ]
Al-Zaheri, Z. M. [1 ]
Alsayed, S. H. [1 ]
Abbas, H. [2 ]
机构
[1] King Saud Univ, Dept Civil Engn, Riyadh 11421, Saudi Arabia
[2] King Saud Univ, Dept Civil Engn, Chair Res & Studies Strengthening & Rehabil Struc, Riyadh 11421, Saudi Arabia
关键词
Masonry wall; Out-of-plane behavior; Fiber-reinforced polymer (FRP); Flexural strengthening; Analytical modeling; MASONRY WALLS;
D O I
10.1061/(ASCE)CC.1943-5614.0000695
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of externally bonded fiber-reinforced polymer (FRP) composites for upgrading the out-of-plane flexural resistance of unreinforced masonry (URM) walls is experimentally and analytically investigated in this study. A total of six hollow concrete block walls were tested to failure using an airbag and a reaction frame to obtain a uniform load on the wall. The masonry walls were placed horizontally and tested as one-way slabs with span direction perpendicular to the bed joints. The first wall was left unstrengthened to be used as control specimen; the other five walls were strengthened using different schemes of externally attached glass-fiber-reinforced polymer (GFRP) sheets. The main parameters studied experimentally were FRP reinforcement ratio and stiffness. In addition to the experimental program, an analytical model was developed to predict the ultimate moment capacity of the URM walls. The procedure outlined in standard guidelines was also utilized to compute the flexural capacity of walls. Besides the URM wall specimens tested in this study, another 42 test results of URM walls available in literature were used for analytical model validation. A design model was also proposed and new design aspects were introduced. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:16
相关论文
共 39 条
[31]   Strengthening of masonry walls against out-of-plane loads using fiber-reinforced polymer reinforcement [J].
Tan, KH ;
Patoary, MKH .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (01) :79-87
[32]  
Triantafillou T. C., J COMPOS CONSTR, V2, P96
[33]   Field assessment of unreinforced masonry walls strengthened with fiber reinforced polymer laminates [J].
Tumialan, JG ;
Galati, N ;
Nanni, A .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (08) :1047-1056
[34]  
Tumialan JG, 2003, ACI STRUCT J, V100, P321
[35]  
Tumialan JG, 2002, 3 INT C COMP INFR IC
[36]  
*UBC, 1991, INT C BUILD OFF WHIT
[37]   Out-of-plane behaviour of infill masonry panels strengthened with composite materials [J].
Valluzzi, Maria Rosa ;
da Porto, Francesca ;
Garbin, Enrico ;
Panizza, Matteo .
MATERIALS AND STRUCTURES, 2014, 47 (12) :2131-2145
[38]   MODELING OUT-OF-PLANE BEHAVIOR OF URM WALLS RETROFITTED WITH FIBER COMPOSITES [J].
Velazquez-Dimas, J. I. ;
Ehsani, M. R. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2000, 4 (04) :172-181
[39]  
Velazquez-Dimas JI, 2000, ACI STRUCT J, V97, P377