Rapid and Sensitive Detection of Aflatoxin B1, B2, G1 and G2 in Vegetable Oils Using Bare Fe3O4 as Magnetic Sorbents Coupled with High-Performance Liquid Chromatography with Fluorescence Detection

被引:18
作者
Zhang, Hui-Xian [1 ]
Zhang, Ping [2 ]
Fu, Xiao-Fang [3 ]
Zhou, You-Xiang [1 ]
Peng, Xi-Tian [1 ]
机构
[1] Hubei Acad Agr Sci, Hubei Key Lab Nutr Qual & Safety Agro Prod, Inst Agr Qual Stand & Testing Technol Res, Wuhan 430064, Hubei, Peoples R China
[2] Liupanshui Normal Univ, Sch Chem & Mat Engn, Liupanshui 553004, Guizhou, Peoples R China
[3] Technol Ctr Wuhan Customs Dist, Wuhan 430036, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
SOLID-PHASE EXTRACTION; EDIBLE OILS; IMMUNOAFFINITY COLUMN; B-1; MICROEXTRACTION; MILK; G(1); G(2); PRODUCTS; M1;
D O I
10.1093/chromsci/bmaa026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports a simple, sensitive and reliable method for the simultaneous detection of aflatoxin B1, B2, G1 and G2 in vegetable oils. Aflatoxins were extracted by magnetic solid phase extraction followed by high-performance liquid chromatography, then postcolumn photochemical derivatization and finally detected by fluorescence detector. Vegetable oil samples were first diluted with hexane and then commercial bare Fe3O4 nanoparticles were directly employed as sorbents to extract aflatoxins from complex vegetable oil samples, which significantly simplified the procedure of sample preparation and largely improved the sample analysis throughput. The effects of various parameters such as the amount of sorbent, loading, washing and eluting conditions were carefully optimized to improve the extraction efficiencies of aflatoxins. Under the optimal conditions, the limits of detection of four aflatoxins ranged from 0.01 mu g/kg to 0.16 mu g/kg, and squared regression coefficients (R-2) >0.9990 were obtained within the linear range of 0.1-20 mu g/kg (except for aflatoxin G2 with 0.5-20 mu g/kg). Furthermore, the recoveries spiked at four concentration levels in a blank vegetable oil sample were from 82.6 to 106.2%, with inter- and intraday relative standard deviations <9.8%, indicating good accuracy and precision of the proposed method.
引用
收藏
页码:678 / 685
页数:8
相关论文
共 32 条
  • [1] A novel method for high preconcentration of ultra trace amounts of B1, B2, G1 and G2 aflatoxins in edible oils by dispersive liquid-liquid microextraction after immunoaffinity column clean-up
    Afzali, Daryoush
    Ghanbarian, Maryam
    Mostafavi, Ali
    Shamspur, Tayebeh
    Ghaseminezhad, Sima
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1247 : 35 - 41
  • [2] Application of dispersive liquid-liquid microextraction coupled with vortex-assisted hydrophobic magnetic nanoparticles based solid-phase extraction for determination of aflatoxin M1 in milk samples by sensitive micelle enhanced spectrofluorimetry
    Amoli-Diva, Mitra
    Taherimaslak, Zohreh
    Allahyari, Mehdi
    Pourghazi, Kamyar
    Manafi, Mohammad Hanif
    [J]. TALANTA, 2015, 134 : 98 - 104
  • [3] Simultaneous analysis of aflatoxins BI, B2, G-1, G2, M-1 and ochratoxin A in breast milk by high-performance liquid chromatography/fluorescence after liquid-liquid extraction with low temperature purification (LLE-LTP)
    Andrade, Patricia Diniz
    Gomes da Silva, Julyane Laine
    Caldas, Eloisa Dutra
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1304 : 61 - 68
  • [4] Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains
    Asghar, Muhammad Asif
    Iqbal, Javed
    Ahmed, Aftab
    Khan, Mobeen Ahmed
    Shamsuddin, Zuzzer Ali
    Jamil, Khalid
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 2016, 32 (06) : 1122 - 1134
  • [5] Bao L, 2010, J AOAC INT, V93, P936
  • [6] Challenges and issues concerning mycotoxins contamination in oil seeds and their edible oils: Updates from last decade
    Bhat, Rajeev
    Reddy, Kasa Ravindra Nadha
    [J]. FOOD CHEMISTRY, 2017, 215 : 425 - 437
  • [7] Rapid and high-throughput determination of endogenous cytokinins in Oryza sativa by bare Fe3 O4 nanoparticles-based magnetic solid-phase extraction
    Cai, Bao-Dong
    Zhu, Jiu-Xia
    Gao, Qiang
    Luo, Dan
    Yuan, Bi-Feng
    Feng, Yu-Qi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1340 : 146 - 150
  • [8] Application of dispersive liquid-liquid microextraction for the determination of aflatoxins B1, B2, G1 and G2 in cereal products
    Campone, Luca
    Piccinelli, Anna Lisa
    Celano, Rita
    Rastrelli, Luca
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (42) : 7648 - 7654
  • [9] Extended validation of a senstive and robust method for simultaneous quantification of aflatoxins B1, B2, G1 and G2 in Brazil nuts by HPLC-FLD
    Campos, Willison E. O.
    Rosas, Larissa B.
    Neto, Antonio P.
    Mello, Ricardo A.
    Vasconcelos, Arthur A.
    [J]. JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2017, 60 : 90 - 96
  • [10] Multi-residue analysis of pesticides, plant hormones, veterinary drugs and mycotoxins using HILIC chromatography - MS/MS in various food matrices
    Danezis, G. P.
    Anagnostopoulos, C. J.
    Liapis, K.
    Koupparis, M. A.