3-D scapular kinematics during arm elevation: Effect of motion velocity

被引:69
作者
Fayad, F.
Hoffmann, G.
Hanneton, S.
Yazbeck, C.
Lefevre-Colau, M. M.
Poiraudeau, S.
Revel, M.
Roby-Brami, A.
机构
[1] Univ Paris 05, Hop Cochin, Serv Reeduct & Readapat Appareil Locomoteur & Pat, F-75014 Paris, France
[2] Lab Neurophys & Physiol Syst Moteur, UMR 8119, F-75006 Paris, France
[3] INSERM, U472, F-94807 Villejuif, France
[4] INSERM, IFR 25, Inst Federatif Rech Handicap, F-75654 Paris 13, France
关键词
scapula; three-dimensional kinematics; scapulohumeral rhythm; shoulder; arm velocity; electromagnetic tracking device; biomechanics;
D O I
10.1016/j.clinbiomech.2006.04.015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. No three-dimensional (3-D) data exist on the influence of motion velocity on scapular kinematics. The effect of arm elevation velocity has been studied only in a two-dimensional setting. Methods. Thirty healthy subjects performed dominant (right) arm elevation in two planes, sagittal and frontal, and at slow and fast self-selected arm speed. Scapular orientation and humeral elevation were measured at 30 Hz recording frequency with use of a 6-degree-of-freedom electromagnetic system (Polhemus Fastrak(a)). Motion was computed according to the International Society of Biomechanics standards. Scapular orientation was also determined with the arm held in different static positions. Findings. We obtained a full 3-D kinematic description of scapula achieving a reliable, complex 3-D motion during humeral elevation and lowering. The maximal sagittal arm elevation showed a characteristic "M"-shape pattern of protraction/retraction curve. Scapular rotations did not differ significantly between slow and fast movements. Moreover, protraction/retraction and tilt angular values did not differ significantly between static and dynamic tasks. However, scapular lateral rotation values differed between static and dynamic measurements during sagittal and frontal arm elevation. Lateral scapular rotation appears to be less in static than in dynamic measurement, particularly in the sagittal plane. Interpretation. Interpolation of statically recorded positions of the bones cannot reflect the kinematics of the scapula. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:932 / 941
页数:10
相关论文
共 36 条
[1]   The measurement of three dimensional scapulohumeral kinematics - a study of reliability [J].
Barnett, ND ;
Duncan, RDD ;
Johnson, GR .
CLINICAL BIOMECHANICS, 1999, 14 (04) :287-290
[2]   Kinematics of human arm reconstructed from spatial tracking system recordings [J].
Biryukova, EV ;
Roby-Brami, A ;
Frolov, AA ;
Mokhtari, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (08) :985-995
[3]   Comparison of scapular kinematics between elevation and lowering of the arm in the scapular plane [J].
Borstad, JD ;
Ludewig, PM .
CLINICAL BIOMECHANICS, 2002, 17 (9-10) :650-659
[4]  
CHAKRAVARTY K, 1993, J RHEUMATOL, V20, P1359
[5]   SHOULDER DISORDERS IN THE ELDERLY - A COMMUNITY SURVEY [J].
CHARD, MD ;
HAZLEMAN, R ;
HAZLEMAN, BL ;
KING, RH ;
REISS, BB .
ARTHRITIS AND RHEUMATISM, 1991, 34 (06) :766-769
[6]  
Croft P, 1996, BRIT MED J, V313, P601
[7]   Velocity effects on the scapulo-humeral rhythm [J].
de Groot, JH ;
Valstar, ER ;
Anvert, HJ .
CLINICAL BIOMECHANICS, 1998, 13 (08) :593-602
[8]  
Endo K, 2001, J Orthop Sci, V6, P3, DOI 10.1007/s007760170017
[9]   TRANSLATION OF THE HUMERAL HEAD ON THE GLENOID WITH PASSIVE GLENOHUMERAL MOTION [J].
HARRYMAN, DT ;
SIDLES, JA ;
CLARK, JM ;
MCQUADE, KJ ;
GIBB, TD ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (09) :1334-1343
[10]   Scapular Behavior in shoulder impingement syndrome [J].
Hébert, LJ ;
Moffet, H ;
McFadyen, BJ ;
Dionne, CE .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (01) :60-69