Analysis of chlormequat and mepiquat by hydrophilic interaction chromatography coupled to tandem mass spectrometry in food samples

被引:69
作者
Esparza, X. [1 ]
Moyano, E. [1 ]
Galceran, M. T. [1 ]
机构
[1] Univ Barcelona, Fac Chem, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
Quats; HILIC; Food analysis; LC-MS/MS; QUATERNARY AMMONIUM HERBICIDES; LIQUID-CHROMATOGRAPHY; POLAR COMPOUNDS; REVERSED-PHASE; SILICA COLUMNS; RESIDUES; PEARS; PESTICIDES; TOMATO; GRAIN;
D O I
10.1016/j.chroma.2009.03.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work a LC-MS/MS method for the determination of two quaternary ammonium growth regulators (chlormequat and mepiquat) in food is reported. The separation was based on hydrophilic interaction liquid chromatography (HILIC) without the use of ion-pair reagents. A gradient elution of acetonitrile and formic acid/ammonium formate buffer from 60 to 40% acetonitrile was enough to achieve a resolution >1.5 in less than 4.0 min. The HILIC system was coupled to a triple quadrupole mass spectrometer equipped with a heated electrospray probe (H-ESI) providing sub-pg LODs in SRM mode. A straightforward sample treatment (SPE C18 clean-up) was enough to provide MLODs at low ppb levels when analysing a range of food samples that covered different kinds of matrices such as fresh fruit, vegetables, fruit juices, baby food, bread, coffee and beer. Chlormequat was found in seven samples (0.8-126 ng/g) but mepiquat was only detected in bread and coffee samples (0.9-166 ng/g). (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:4402 / 4406
页数:5
相关论文
共 30 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   Determination of diquat and paraquat in olive oil by ion-pair liquid chromatography-electro spray ionization mass spectrometry (MRM) [J].
Aramendía, MA ;
Borau, V ;
Lafont, F ;
Marinas, A ;
Marinas, JM ;
Moreno, JM ;
Porras, JM ;
Urbano, FJ .
FOOD CHEMISTRY, 2006, 97 (01) :181-188
[3]   Rapid method for determination of chlormequat residues in tomato products by ion-exchange liquid chromatography/electrospray tandem mass spectrometry [J].
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (19) :1821-1826
[4]   Ion-pair liquid chromatography atmospheric pressure ionization mass spectrometry for the determination of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :145-154
[5]   Determination of quaternary ammonium pesticides by liquid chromatography-electrospray tandem mass spectrometry [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) :111-121
[6]   On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :441-449
[7]   Improved sensitivity in detection of chlormequat by liquid chromatography-mass spectrometry [J].
Evans, CS ;
Startin, JR ;
Goodall, DM ;
Keely, BJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 897 (1-2) :399-404
[8]  
Evans CS, 2000, RAPID COMMUN MASS SP, V14, P112, DOI 10.1002/(SICI)1097-0231(20000130)14:2<112::AID-RCM841>3.0.CO
[9]  
2-0
[10]   Tandem mass spectrometric analysis of quaternary ammonium pesticides [J].
Evans, CS ;
Startin, JR ;
Goodall, DM ;
Keely, BJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (09) :699-707