Remineralization potential of nano-hydroxyapatite on enamel and cementum surrounding margin of computer-aided design and computer-aided manufacturing ceramic restoration

被引:31
|
作者
Juntavee, Niwut [1 ]
Juntavee, Apa [2 ]
Plongniras, Preeyarat [3 ]
机构
[1] Khon Kaen Univ, Dept Prosthodont, Fac Dent, 123 Mitraphap Rd, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Dept Pediat Dent, Fac Dent, Khon Kaen, Thailand
[3] Khon Kaen Univ, Div Biomat & Prosthodont Res, Fac Dent, Khon Kaen, Thailand
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2018年 / 13卷
关键词
biomimetics; CAD-CAM; cavosurface margin; root caries; zirconia; IN-VITRO; CROWN MARGIN; CARIES; LESIONS; NANOTECHNOLOGY; OSTEOPOROSIS; DENTISTRY; SURFACE;
D O I
10.2147/IJN.S165080
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Objective: This study investigates the effects of nano-hydroxyapatite (NHA) gel and Clinpro (CP) on remineralization potential of enamel and cementum at the cavosurface area of computer-aided design and computer-aided manufacturing ceramic restoration. Materials and methods: Thirty extracted human mandibular third molars were sectioned at 1 mm above and below the cemento-enamel junction to remove the cemento-enamel junction portions and replaced them with zirconia ceramic disks by bonding them to the crown and root portions with resin cement. The enamel and cementum with an area of 4x4 mm(2) surrounding the ceramic disk was demineralized with carbopol. The demineralized surfaces were treated with either NHA or CP, while 1 group was left with no treatment. Vickers microhardness of enamel and cementum were determined before demineralization, after demineralization, and after remineralization. Analysis of variance and Tukey multiple comparisons were used to determine statistically significant differences at 95% level of confidence. Scanning electron microscopy and X-ray diffraction were used to evaluate for surface alterations. Results: The mean +/- SD of Vickers microhardness for before demineralization, after demineralization, and after remineralization for enamel and cementum were 377.37 +/- 22.99, 161.95 +/- 10.54, 161.70 +/- 5.92 and 60.37 +/- 3.81, 17.65 +/- 0.91, 17.04 +/- 1.00 for the no treatment group; 378.20 +/- 18.76, 160.72 +/- 8.38, 200.08 +/- 8.29 and 62.58 +/- 3.37, 18.38 +/- 1.33, 27.99 +/- 2.68 for the NHA groups; and 380.53 +/- 25.14, 161.94 +/- 5.66, 193.16 +/- 7.54 and 62.78 +/- 4.75, 19.07 +/- 1.30, 24.46 +/- 2.02 for the CP groups. Analysis of variance indicated significant increase in microhardness of demineralized enamel and cementum upon the application of either NHA or CP (p<0.05). Post hoc multiple comparisons indicated significantly higher remineralization capability of NHA for both enamel and cementum than CP (p<0.05), as evidenced by scanning electron microscopy, indicating NHA particle deposition in the area of remineralization, and crystallinity accumulation, as indicated by X-ray diffraction. Conclusion: NHA gel and CP were capable of remineralization of the enamel and cementum. NHA was more capable in the remineralization process than CP. NHA was extremely capable in the remineralization process for enamel and cementum surrounding the margin of the computer-aided design and computer-aided manufacturing ceramic.
引用
收藏
页码:2755 / 2765
页数:11
相关论文
共 50 条
  • [1] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING
    WEINBERGSTABER, M
    DU-DIE ZEITSCHRIFT DER KULTUR, 1984, (02): : 89 - 89
  • [2] Bioprinting of Multimaterials with Computer-aided Design/Computer-aided Manufacturing
    Lee, J. M.
    Sing, S. L.
    Yeong, W. Y.
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2020, 6 (01) : 65 - 73
  • [3] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING OF FOOT ORTHOSES
    STAATS, TB
    KRIECHBAUM, MP
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 1 (03) : 182 - 186
  • [4] Restoration of a Mandibular Incisor With a Computer-aided Design/Computer-aided Manufacturing Fabricated Anterior Onlay
    May, J.
    Watson, J.
    OPERATIVE DENTISTRY, 2019, 44 (02) : 109 - 113
  • [5] To Computer-Aided Design and Manufacturing or Not to Computer-Aided Design and Manufacturing? Free Fibula Flap With Computer-Aided Technique for Mandibular Reconstruction
    Zavattero, Emanuele
    Garzino-Demo, Paolo
    Fasolis, Massimo
    Ramieri, Guglielmo
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : E206 - E209
  • [6] Computer-aided design/computer-aided manufacturing skull base drill
    Couldwell, William T.
    MacDonald, Joel D.
    Thomas, Charles L.
    Hansen, Bradley C.
    Lapalikar, Aniruddha
    Thakkar, Bharat
    Balaji, Alagar K.
    NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [7] Computer-aided design and Computer-aided engineering
    Kolbasin, Alexander
    Husu, Oksana
    INTERNATIONAL SCIENCE CONFERENCE SPBWOSCE-2017 BUSINESS TECHNOLOGIES FOR SUSTAINABLE URBAN DEVELOPMENT, 2018, 170
  • [8] Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments
    Stona, Deborah
    Henrique, Luiz
    Burnett, Luiz Henrique, Jr.
    Mota, Eduardo Goncalves
    Spohr, Ana Maria
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2015, 146 (07): : 501 - 507
  • [10] Radiopacity of computer-aided design/computer-aided manufacturing composite resin blocks
    Koizumi, Hiroyasu
    Okamura, Kentaro
    Hiraba, Haruto
    Kodaira, Akihisa
    Yoneyama, Takayuki
    Matsumura, Hideo
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2020, 128 (03) : 241 - 245