Reproducibility of home blood pressure measurements over a 1-year period

被引:99
作者
Sakuma, M
Imai, Y
Nagai, K
Watanabe, N
Sakuma, H
Minami, N
Satoh, H
Abe, K
机构
[1] TOHOKU UNIV,SCH MED,DEPT MED 2,AOBA KU,SENDAI,MIYAGI 98077,JAPAN
[2] TOHOKU UNIV,SCH MED,DEPT ENVIRONM HLTH SCI,SENDAI,MIYAGI 98077,JAPAN
[3] OHASAMA HOSP,IWATE,JAPAN
关键词
reproducibility; blood pressure; home measurements; screening measurements;
D O I
10.1016/S0895-7061(97)00117-9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We compared the reproducibility over time of blood pressure measured at the health examinations (screening blood pressure) and blood pressure measured at home (home blood pressure). Both screening and home blood pressure were measured in subjects of a rural community. Subjects measured their own blood pressure at home once in the morning using a semiautomatic oscillometric blood pressure measuring device at least three times (on at least 3 days) in each of two 4-week periods separated by one year. Similarly, two screening blood pressure measurements were obtained from the subjects at each of two health examinations also taken 1 year apart. A total of 136 untreated subjects without cardiovascular complications (40 men and 96 women, 56 +/- 11.7 years, mean +/- SD) were analyzed in the study. The correlations between the first and second blood pressure measurements of the subjects were significantly higher for the home blood pressure measurements (systolic: r = 0.844 and diastolic: r = 0.830) than for the screening blood pressure measurements (systolic: r = 0.692 and diastolic: r = 0.570). The mean differences between the first and second home blood pressure (0.8 +/- 7.7 mm Hg for systolic BP and 0.9 +/- 5.5 mm Hg for diastolic BP) were significantly smaller than those for the screening blood pressure (-3.9 +/- 13.8 for systolic BP and -3.1 +/- 10.2 for diastolic BP) (P < .001 for both comparisons), suggesting that the reproducibility of home blood pressure over time is superior to that of screening blood pressure. Such reliable blood pressure measurements obtained at home have a clinical significance for the diagnosis and treatment of hypertension and as a tool for evaluating the efficacy of antihypertensive drugs. Home blood pressure measurements also may be more useful than screening blood pressure measurements in predicting future cardiovascular events. (C) 1997 American Journal of Hypertension, Ltd.
引用
收藏
页码:798 / 803
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 1987, AM NAT STAND EL AUT
[2]   AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE SELF-MEASUREMENT IN THE DIAGNOSIS AND MANAGEMENT OF HYPERTENSION [J].
APPEL, LJ ;
STASON, WB .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (11) :867-882
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   USEFULNESS OF HOME BP DETERMINATION IN TREATING BORDERLINE HYPERTENSION [J].
COTTIER, C ;
JULIUS, S ;
GAJENDRAGADKAR, SV ;
SCHORK, MA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 248 (05) :555-558
[5]   Circadian blood pressure variation related to morbidity and mortality from cerebrovascular and cardiovascular diseases [J].
Imai, Y ;
Tsuji, I ;
Nagai, K ;
Watanabe, N ;
Ohkubo, T ;
Sakuma, M ;
Hashimoto, J ;
Itoh, O ;
Satoh, H ;
Hisamichi, S ;
Abe, K .
TIME-DEPENDENT STRUCTURE AND CONTROL OF ARTERIAL BLOOD PRESSURE, 1996, 783 :172-185
[6]   AMBULATORY BLOOD-PRESSURE OF ADULTS IN OHASAMA, JAPAN [J].
IMAI, Y ;
NAGAI, K ;
SAKUMA, M ;
SAKUMA, H ;
NAKATSUKA, H ;
SATOH, H ;
MINAMI, N ;
MUNAKATA, M ;
HASHIMOTO, J ;
YAMAGISHI, T ;
WATANABE, N ;
YABE, T ;
NISHIYAMA, A ;
ABE, K .
HYPERTENSION, 1993, 22 (06) :900-912
[7]   CHARACTERISTICS OF A COMMUNITY-BASED DISTRIBUTION OF HOME BLOOD-PRESSURE IN OHASAMA IN NORTHERN JAPAN [J].
IMAI, Y ;
SATOH, H ;
NAGAI, K ;
SAKUMA, M ;
SAKUMA, H ;
MINAMI, N ;
MUNAKATA, M ;
HASHIMOTO, J ;
YAMAGISHI, T ;
WATANABE, N ;
YABE, T ;
NISHIYAMA, A ;
NAKATSUKA, H ;
KOYAMA, H ;
ABE, K .
JOURNAL OF HYPERTENSION, 1993, 11 (12) :1441-1449
[8]   Seasonal variation in blood pressure in normotensive women studied by home measurements [J].
Imai, Y ;
Munakata, M ;
Tsuji, I ;
Ohkubo, T ;
Satoh, H ;
Yoshino, H ;
Watanabe, N ;
Nishiyama, A ;
Onodera, N ;
Kato, J ;
Sekino, M ;
Aihara, A ;
Kasai, Y ;
Abe, K .
CLINICAL SCIENCE, 1996, 90 (01) :55-60
[9]   CLINICAL-EVALUATION OF SEMIAUTOMATIC AND AUTOMATIC DEVICES FOR HOME BLOOD-PRESSURE MEASUREMENT - COMPARISON BETWEEN CUFF-OSCILLOMETRIC AND MICROPHONE METHODS [J].
IMAI, Y ;
ABE, K ;
SASAKI, S ;
MINAMI, N ;
MUNAKATA, M ;
SAKUMA, H ;
HASHIMOTO, J ;
SEKINO, H ;
IMAI, K ;
YOSHINAGA, K .
JOURNAL OF HYPERTENSION, 1989, 7 (12) :983-990
[10]   CLINICAL-SIGNIFICANCE AND COST-EFFECTIVENESS OF 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING [J].
IMAI, Y .
TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1995, 176 (01) :1-15